Fluorescent paper–based sensor based on carbon dots for detection of folic acid
- 20 February 2020
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (12) , 2805-2813
Abstract
Paper-based devices have been very much in the foreground of analytical science recently. This work innovatively proposed a fluorescent paper–based sensor (FPS) constructed on a hybrid polydimethylsiloxane (PDMS)/paper platform where cellulose papers functionalized with carbon dots (CDs) as fluorophores by Schiff base chemistry were loaded on the grooves array of a designed PDMS plate. As a proof of concept, the performance of FPS was investigated with folic acid (FA) as the target analyte. Under optimal conditions, FPS enabled a rapid fluorescence quenching response to FA via inner filter effect in a wide range of 1–300 μmol L−1 with the limit of detection of 0.28 μmol L−1. The feasibility of FPS was further verified by the detection of FA in orange juice and urine samples with satisfactory results. The covalent modification of CDs on paper endowed the FPS with good assay reproducibility and stability. Interestingly, FPS achieved a more sensitive assay of FA than the conventional strategy, by which the same CDs were directly used to detect FA in a solution-based system. The FPS illuminated a novel strategy for construction of reliable and sensitive assays based on paper-based devices. It is of paramount importance for its practical application in biosensing and clinical diagnosis. Graphical abstractKeywords
This publication has 45 references indexed in Scilit:
- Copper- or manganese-doped ZnS quantum dots as fluorescent probes for detecting folic acid in aqueous mediaJournal of Luminescence, 2012
- Synchronous Fluorescence as a Rapid Method for the Simultaneous Determination of Folic Acid and Riboflavin in Nutritional BeveragesJournal of Agricultural and Food Chemistry, 2011
- A Binary Functional Substrate for Enrichment and Ultrasensitive SERS Spectroscopic Detection of Folic Acid Using Graphene Oxide/Ag Nanoparticle HybridsACS Nano, 2011
- New strategy for simultaneous and selective voltammetric determination of norepinephrine, acetaminophen and folic acid using ZrO2 nanoparticles-modified carbon paste electrodeSensors and Actuators B: Chemical, 2010
- Determination of Folic Acid by CE in Various Cultivated Variety of LentilsChromatographia, 2010
- Modified multiwall carbon nanotubes paste electrode as a sensor for simultaneous determination of 6-thioguanine and folic acid using ferrocenedicarboxylic acid as a mediatorJournal of Electroanalytical Chemistry, 2010
- Electrocatalytic Oxidation of Folic Acid on Carbon Paste Electrode Modified by Nickel Ions Dispersed into Poly(o‐anisidine) FilmElectroanalysis, 2009
- Disposable microfluidic ELISA for the rapid determination of folic acid content in food productsAnalytical and Bioanalytical Chemistry, 2006
- Determination of folate in some cereals and commercial cereal-grain products consumed in Poland using trienzyme extraction and high-performance liquid chromatography methodsEuropean Food Research and Technology, 2005
- Determination of folates in seaweeds by high-performance liquid chromatographyJournal of Chromatography A, 2004