Shape-Sensing Robotic Bronchoscopy with Integrated Mobile Cone-Beam CT Guidance for Intraoperative Localization of Lung Tumors Using Indocyanine Green
Open Access
- 18 June 2026
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1893
Abstract
Background/Objectives: With increasing frequency in sublobar resections, accurate intraoperative localization has become essential to ensure adequate resection margins and spare lung parenchyma. Our study evaluates the efficacy of shape-sensing robotic bronchoscopy (SS-RAB) with integrated mobile cone-beam CT (mCBCT) for intraoperative localization of lung tumors using indocyanine green (ICG). We further aimed to explore the feasibility of a single intubation-single positioning technique for bronchoscopy and surgery. Methods: We retrospectively reviewed patients who underwent SS-RAB with integrated mCBCT for ICG marking, followed by minimally invasive sublobar resection. ICG marking was deemed successful when it allowed the operative team to localize and resect the lesion with adequate pathology margins. Results: A total of 28 patients with 30 pulmonary lesions from a single institution were included. Median tumor size was 10.5 mm (IQR, 8.7–14.6 mm) and distance from pleura 7.8 mm (IQR, 2.45–13.8 mm). Twenty lesions (66.6%) were solid, 5 lesions (16.6%) semi-solid, and 5 lesions (16.6%) ground-glass. ICG localization was successful in 28 lesions (93%). Nineteen patients (68%) were intubated only with a double-lumen endotracheal tube (DL-ETT), used for bronchoscopy and surgery, and in 10 patients (36%) ICG marking and surgery were both performed in lateral decubitus. One patient developed a small pneumothorax during bronchoscopy which did not prevent ICG injection. Conclusions: SS-RAB with integrated mCBCT for ICG marking is successful and safe. Single intubation with DL-ETT and lateral decubitus positioning for both bronchoscopy and surgery are feasible. Further studies are needed to prove a potential increase in efficiency with this technique.Keywords
This publication has 34 references indexed in Scilit:
- Superiority of Lateral Decubitus Strategy in Preventing Atelectasis From Obscuring Targets During Robotic BronchoscopyChest, 2026
- Lung Tumors Marked Percutaneously with Indocyanine Green Dye–Soaked Embolization Coils: A Visual Beacon for Accurate Intraoperative Localization during Lung-Sparing SurgeryJournal of Vascular and Interventional Radiology, 2025
- Lung Nodule Marking With ICG Dye–Soaked Coil Facilitates Localization and Delayed Surgical ResectionAnnals of Thoracic Surgery Short Reports, 2023
- Ventilatory Strategy to Prevent Atelectasis During Bronchoscopy Under General AnesthesiaChest, 2022
- Combining Shape-Sensing Robotic Bronchoscopy With Mobile Three-Dimensional Imaging to Verify Tool-in-Lesion and Overcome Divergence: A Pilot StudyMayo Clinic Proceedings: Innovations, Quality & Outcomes, 2022
- NAVIGATE 24-Month Results: Electromagnetic Navigation Bronchoscopy for Pulmonary Lesions at 37 Centers in Europe and the United StatesJournal of Thoracic Oncology, 2022
- Incidence and Location of Atelectasis Developed During Bronchoscopy Under General AnesthesiaChest, 2020
- Technique, Outcomes With Navigational Bronchoscopy Using Indocyanine Green for Robotic SegmentectomyThe Annals of Thoracic Surgery, 2019
- Standard Bronchoscopy With Fluoroscopy vs Thin Bronchoscopy and Radial Endobronchial Ultrasound for Biopsy of Pulmonary LesionsChest, 2018
- Comparative Effectiveness and Safety of Preoperative Lung Localization for Pulmonary NodulesChest, 2017