Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 – practical use, including problems, and their use with paediatric patients
Author:
- 30 November 2010
- journal article
- review article
- Published by Wiley in Anaesthesia
- Vol. 66 (1) , 40-51
Abstract
Summary: Heat and moisture exchangers and breathing system filters are intended to replace the normal warming, humidifying and filtering functions of the upper airways. The first part of this review considered the history, principles of operation and efficiency of these devices. The aim of this part of the review is to summarise recent guidelines on the use of these devices and outline the problems that can occur. In particular, the effect of these devices on gas analysis, dead space, resistance to gas flow and blockage of the breathing system is considered. In children, it is important to consider the addition of dead space and resistance to gas flow. A body weight of 2.5 kg is probably the lower weight limit for use with heat and moisture exchangers, and 3 kg for filters. The resistance to gas flow of a heat‐ and moisture‐exchanging filter added to a Mapleson F breathing system can cause a delay in the induction of anaesthesia.Keywords
This publication has 102 references indexed in Scilit:
- Infection control in mass respiratory failure: Preparing to respond to H1N1Critical Care Medicine, 2010
- Ventilator management for hypoxemic respiratory failure attributable to H1N1 novel swine origin influenza virusCritical Care Medicine, 2010
- Infection Control in AnaesthesiaAnaesthesia, 2008
- Avian flu (H5N1): its epidemiology, prevention, and implications for anesthesiologyJournal of Clinical Anesthesia, 2006
- The benefit of using a heat and moisture exchanger during short operations in young childrenPediatric Anesthesia, 1997
- Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failureCritical Care Medicine, 1996
- The effect of a heat and moisture exchange filter on sidestream spirometry in critically ill patientsJournal of Clinical Monitoring and Computing, 1994
- Use of heat and moisture exchanging (HME) filters in mechanically ventilated ICU patients: Influence on airway flow-resistanceIntensive Care Medicine, 1993
- Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilationIntensive Care Medicine, 1992
- Effects of the heat-moisture exchangers on dynamic hyperinflation of mechanically ventilated COPD patientsIntensive Care Medicine, 1990