Projection angle dependence in grating-based X-ray dark-field imaging of ordered structures
Open Access
- 16 August 2013
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (17) , 19922-19933
Abstract
Over the recent years X-ray differential phase-contrast imaging was developed for the hard X-ray regime as produced from laboratory X-ray sources. The technique uses a grating-based Talbot-Lau interferometer and was shown to yield image contrast gain, which makes it very interesting to the fields of medical imaging and non-destructive testing, respectively. In addition to X-ray attenuation contrast, the differential phase-contrast and dark-field images provide different structural information about a specimen. For the dark-field even at length scales much smaller than the spatial resolution of the imaging system. Physical interpretation of the dark-field information as present in radiographic and tomographic (CT) images requires a detailed look onto the geometric orientation between specimen and the setup. During phase-stepping the drop in intensity modulation, due to local scattering effects within the specimen is reproduced in the dark-field signal. This signal shows strong dependencies on micro-porosity and micro-fibers if these are numerous enough in the object. Since a grating-interferometer using a common unidirectional line grating is sensitive to X-ray scattering in one plane only, the dark-field image is influenced by the fiber orientations with respect to the grating bars, which can be exploited to obtain anisotropic structural information. With this contribution, we attempt to extend existing models for 2D projections to 3D data by analyzing dark-field contrast tomography of anisotropically structured materials such as carbon fiber reinforced carbon (CFRC).Keywords
This publication has 16 references indexed in Scilit:
- Orientation-selective X-ray dark field imaging of ordered systemsJournal of Applied Physics, 2012
- Spectroscopic dark-field imaging using a grating-based Talbot-Lau interferometer2012
- Sub-pixel porosity revealed by x-ray scatter dark field imagingJournal of Applied Physics, 2011
- Quantitative x-ray dark-field computed tomographyPhysics in Medicine & Biology, 2010
- On the origin of visibility contrast in x-ray Talbot interferometryOptics Express, 2010
- Spatial Harmonic Imaging of X-ray Scattering—Initial ResultsIEEE Transactions on Medical Imaging, 2008
- Hard-X-ray dark-field imaging using a grating interferometerNature Materials, 2008
- Phase Tomography by X-ray Talbot Interferometry for Biological ImagingJapanese Journal of Applied Physics, 2006
- X-ray phase imaging with a grating interferometerOptics Express, 2005
- Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x raysApplied Physics Letters, 1999