In this paper, a power compensator using supercapacitors in parallel to protect grid-connected devices connected to the distributed power supply in the case of a low-voltage ride-through (LVRT) situation in designed, and a grid-connected device control method with improved responsiveness is proposed. In the LVRT situation, the distributed generation power may boost the DC_link voltage, increasing the risk of destroying grid-connected devices. To prevent this, the power compensator designed in this study absorbs active power in a fault situation and stores it in the supercapacitor to suppress the DC_link voltage rise and efficiently use the power. In addition, we propose methods to improve the response of the grid reactive power through the reactive power compensation of the power compensator in LVRT situation. To this end, the power angle (θPW) was extracted through the formula, and the reactive power command, to be compensated by the power compensator, and the reactive power command, compensated by the grid-connected devices, were calculated according to the active power value. In this way, the grid power controlled by the power compensation device and the grid-connected devices was controlled by the active/reactive power of the same power angle and analyzed mathematically. Active power control and static grid support were performed in the normal state where the reduction rate of the normal value of the grid voltage was around 10%. However, when the grid voltage dropped by 10% to 100%, the reactive power control was appropriately performed with dynamic grid support by increasing the voltage from 10% to 20% or more. We conducted a simulation of the new and renewable energy grid-connected devices using the OPAL-RT-based Hardware-in-the Loop Simulation (HILS) system to control the proposed active/reactive power.Keywords
This publication has 16 references indexed in Scilit:
- Optimal Control and Placement of Step Voltage Regulator for Voltage Unbalance Improvement and Loss Minimization in Distribution System2020
- Adaptive virtual inertia-based frequency regulation in wind power systemsRenewable Energy, 2018
- LVRT control strategy of VSC-HVDC connected large PV plant2017
- Reactive Power Management for Overvoltage Prevention at High PV Penetration in a Low-Voltage Distribution SystemIEEE Transactions on Industry Applications, 2017
- Analysis on renewable energy systemsRenewable and Sustainable Energy Reviews, 2013
- Implemental Control Strategy for Grid Stabilization of Grid-Connected PV System Based on German Grid Code in Symmetrical Low-to-Medium Voltage NetworkIEEE Transactions on Energy Conversion, 2013
- Low-Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage GridInternational Journal of Photoenergy, 2013
- Low Voltage Ride Through(LVRT) control strategy of grid-connected variable speed Wind Turbine Generator System2011
- Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors (March 2007)IEEE Transactions on Power Systems, 2007
- Analysis of multiphase space vector pulse-width modulation based on multiple d-q spaces conceptIEEE Transactions on Power Electronics, 2005