Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contour
Authors:
Open Access
- 26 September 2012
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 27 (1) , 25-36
Abstract
Introduction A physical 3-dimensional phantom that simulates PET/SPECT images of static regional cerebral blood flow in grey matter with a realistic head contour has been developed. This study examined the feasibility of using this phantom for evaluating PET/SPECT images. Methods The phantom was constructed using a transparent, hydrophobic photo-curable polymer with a laser-modelling technique. The phantom was designed to contain the grey matter, the skull, and the trachea spaces filled with a radioactive solution, a bone-equivalent solution of K2HPO4, and air, respectively. The grey matter and bone compartments were designed to establish the connectivity. A series of experiments was performed to confirm the accuracy and reproducibility of the phantom using X-ray CT, SPECT, and PET. Results The total weight was 1997 ± 2 g excluding the inner liquid, and volumes were 563 ± 1 and 306 ± 2 mL, corresponding to the grey matter and bone compartments, respectively. The apparent attenuation coefficient averaged over the whole brain was 0.168 ± 0.006 cm−1 for Tc-99 m, which was consistent with the previously reported value for humans (0.168 ± 0.010 cm−1). Air bubbles were well removed from both grey-matter and bone compartments, as confirmed by X-ray CT. The phantom was well adapted to experiments using PET and SPECT devices. Conclusion The 3-dimensional brain phantom constructed in this study may be of use for evaluating the adequacy of SPECT/PET reconstruction software programs.Keywords
This publication has 17 references indexed in Scilit:
- Multicenter Evaluation of a Standardized Protocol for Rest and Acetazolamide Cerebral Blood Flow Assessment Using a Quantitative SPECT Reconstruction Program and Split-Dose 123I-IodoamphetamineJournal of Nuclear Medicine, 2010
- Combination of Converging Collimators for High-Sensitivity Brain SPECTJournal of Nuclear Medicine, 2009
- Reducing between scanner differences in multi-center PET studiesNeuroImage, 2009
- Absolute quantitation of myocardial blood flow with 201Tl and dynamic SPECT in canine: optimisation and validation of kinetic modellingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Bone equivalent liquid solution to assess accuracy of transmission measurements in SPECT and PETIEEE Transactions on Nuclear Science, 1997
- Minimum cross-entropy reconstruction of PET images using prior anatomical informationPhysics in Medicine & Biology, 1996
- Evaluation of SPET quantification of simultaneous emission and transmission imaging of the brain using a multidetector SPET system with the TEW scatter compensation method and fan-beam collimationEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine CommitteeMedical Physics, 1995
- Measurement of Radiotracer Concentration in Brain Gray Matter Using Positron Emission Tomography: MRI-Based Correction for Partial Volume EffectsJournal of Cerebral Blood Flow & Metabolism, 1992
- 3-D phantom to simulate cerebral blood flow and metabolic images for PETIEEE Transactions on Nuclear Science, 1990