Relative response of alanine dosemeters for high-energy electrons determined using a Fricke primary standard
Authors:
- Sándor VörösSVSándor Vörös
- Mathias AntonMAMathias Anton
- Bénédicte BoillatBBBénédicte Boillat
- 21 February 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (5) , 1413-1432
Abstract
A significant proportion of cancer patients is treated using MeV electron radiation. One of the measurement methods which is likely to furnish reliable dose values also under non-reference conditions is the dosimetry using alanine and read-out via electron spin resonance (ESR). The system has already proven to be suitable for QA purposes for modern radiotherapy involving megavoltage x-rays. In order to render the secondary standard measurement system of the Physikalisch-Technische Bundesanstalt based on alanine/ESR useable for dosimetry in radiotherapy, the dose-to-water (D(W)) response of the dosemeter needs to be known for relevant radiation qualities. For MeV electrons, the D(W) response was determined using the Fricke primary standard of the Swiss Federal Office of Metrology. Since there were no citable detailed publications on the Swiss primary standard available, this measurement system is described in some detail. The experimental results for the D(W) response are compared to results of Monte Carlo simulations which model in detail the beams furnished by the electron accelerator as well as the geometry of the detectors. The agreement between experiment and simulation is very good, as well as the agreement with results published by the National Research Council of Canada which are based on a different primary standard. No significant dependence of the D(W) response was found in the range between 6 and 20 MeV. It is therefore suggested to use a unique correction factor k(E) for alanine for all MeV qualities of k(E) = 1.012 ± 0.010.Keywords
This publication has 20 references indexed in Scilit:
- Dose verification and calibration of the Cyberknife® by EPR/alanine dosimetryRadiation Measurements, 2011
- Response of the alanine/ESR dosimetry system to MV x-rays relative to60Co radiationPhysics in Medicine & Biology, 2008
- Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische BundesanstaltPhysics in Medicine & Biology, 2006
- SU-FF-T-195: Dosimetry Audit for Tomotherapy Using Alanine/EPRMedical Physics, 2006
- The PTB water calorimeter for the absolute determination of absorbed dose to water in60Co radiationMetrologia, 2006
- Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry systemApplied Radiation and Isotopes, 2005
- An experimental investigation of the electron energy dependence of the EPR alanine dosimetry systemRadiation Measurements, 2005
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- ESR/alanine dosimetry of high-energy electrons in radiotherapyInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1989
- Determination of the absorbed dose to water for high-energy photons and electrons by total absorption of electrons in ferrous sulphate solutionPhysics in Medicine & Biology, 1982