The electrokinetically pinched method is the most commonly used mode for sample injection in microchip capillary electrophoresis (μCE) due to its simplicity and well‐defined sample volume. However, the limited injection volume and the electrophoretic bias of the pinched injection may limit its universal usage to specific applications. Several hydrodynamic injection methods in μCE have been reported; however, almost all claimed that their methods are bias‐free without considering the dispensing bias. To investigate the dispensing bias, a simple hydrodynamic injection was developed in single‐T and double‐T glass microchips. The sample flow was produced by hydrostatic pressure generated by the liquid level difference between the sample reservoir and the other reservoirs. The reproducibility of peak area and peak area ratio was improved to a significant extent using large‐surface reservoirs for the buffer reservoir and the sample waste reservoir to reduce the Laplace pressure effect. Without a voltage applied on the sample solution, the voltage‐related sample bias was eliminated. The dispensing bias was analyzed theoretically and studied experimentally. It was demonstrated that the dispensing bias existed and could be reduced significantly by appropriately setting up the voltage configuration and by controlling the appropriate liquid level difference.Keywords
This publication has 25 references indexed in Scilit:
- On-Line Sample Preconcentration Using Field-amplified Stacking Injection in Microchip Capillary ElectrophoresisAnalytical Chemistry, 2006
- Estimation of pKa values using microchip capillary electrophoresis and indirect fluorescence detectionJournal of Chromatography B, 2005
- A capillary electrophoresis chip with hydrodynamic sample injection for measurements from a continuous sample flowAnalytical and Bioanalytical Chemistry, 2005
- Pressure Injection on a Valved Microdevice for Electrophoretic Analysis of Submicroliter SamplesAnalytical Chemistry, 2005
- Fluorogenic assay for β-glucuronidase using microchip-based capillary electrophoresisJournal of Chromatography B: Biomedical Sciences and Applications, 2001
- Computer Simulations of Electrokinetic Transport in Microfabricated Channel StructuresAnalytical Chemistry, 1998
- Microchip electrophoresis with sample stackingElectrophoresis, 1995
- Precolumn Reactions with Electrophoretic Analysis Integrated on a MicrochipAnalytical Chemistry, 1994
- Microchip Capillary Electrophoresis with an Integrated Postcolumn ReactorAnalytical Chemistry, 1994
- Effects of Injection Schemes and Column Geometry on the Performance of Microchip Electrophoresis DevicesAnalytical Chemistry, 1994