Solving the iron quantification problem in low-kV EPMA: An essential step toward improved analytical spatial resolution in electron probe microanalysis—Olivines
Authors:
- 1 August 2019
- journal article
- research article
- Published by Mineralogical Society of America in American Mineralogist: Journal of Earth and Planetary Materials
- Vol. 104 (8) , 1131-1142
Abstract
The relatively recent entry of field emission electron microprobes into the field of microanalysis provides another tool for the study of small features of interest (e.g., mineral and melt inclusions, ex-solution lamellae, grain boundary phases, high-pressure experimental charges). However, the critical limitation for accurate quantitative analysis of these submicrometer- to micrometer-sized features is the relationship between electron beam potential and electron scattering within the sample. To achieve submicrometer analytical volumes from which X-rays are generated, the beam accelerating voltage must be reduced from 15–20 to ≤10 kV (often 5 to 7 kV) to reduce the electron interaction volume from ~3 to ~0.5 μm in common geological materials. At these low voltages, critical Kα X-ray lines of transition elements such as Fe are no longer generated, so L X-ray lines must be used. However, applying the necessary matrix corrections to these L lines is complicated by bonding and chemical peak shifts for soft X-ray transitions such as those producing the FeLα X-ray line. It is therefore extremely challenging to produce accurate values for Fe concentration with this approach. Two solutions have been suggested, both with limitations. We introduce here a new, simple, and accurate solution to this problem, using the common mineral olivine as an example. We also introduce, for the first time, olivine results from a new analytical device, the Extended Range Soft X-ray Emission Spectrometer.Keywords
This publication has 26 references indexed in Scilit:
- An Extension up to 4 keV by a Newly Developed Multilayer-Coated Grating for TEM-SXES SpectrometerMicroscopy and Microanalysis, 2011
- Iron speciation using electron microprobe techniques: application to glassy melt pockets within a spinel lherzolite xenolithMineralogical Magazine, 2011
- Getting Started with NIST DTSA-IIMicroscopy Today, 2011
- High-Spatial-Resolution Low-Energy Electron Beam X-Ray MicroanalysisMicrochimica Acta, 2000
- CASINO: A new monte carlo code in C language for electron beam interaction —part I: Description of the programScanning, 1997
- Reference Samples for Electron Microprobe Analysis*Geostandards Newsletter, 1980
- The Pikes Peak batholith, Colorado front range, and a model for the origin of the gabbro—anorthosite—syenite—potassic granite suitePrecambrian Research, 1975
- Empirical Correction Factors for the Electron Microanalysis of Silicates and OxidesThe Journal of Geology, 1968
- The quality of X-ray microanalysis in the ultra-soft X-ray regionBritish Journal of Applied Physics, 1967
- Analyses of cosmic spherules with an X-ray microanalyserGeochimica et Cosmochimica Acta, 1958