Objective: To determine the reliability of pulmonary function testing compared to endoscopic grading in the assessment of subglottic stenosis.Methods: Consecutively treated patients with subglottic stenosis at a tertiary care specialty hospital from 2009 to 2019 were identified. Two fellowship‐trained laryngologists and two otolaryngologists blinded to clinical history reviewed laryngo tracheoscopic examinations and assessed the degree of stenosis using the Cotton‐Myer grading system (% stenosis). Nine full flow‐volume loops were performed at the time of each exam.Results: The endoscopic images of 45 subjects were graded for degree of stenosis and the spirometry data were analyzed. The kappa values for Cotton‐Myer grade overall was 0.37, grade I was −0.103, grade II was 0.052, and grade III was 0.045. The overall intraclass correlation of the physician grading of estimated percent obstruction (% stenosis) was 0.712 (P < .01) whereas the overall intraclass correlation for PEF% was 0.96 (P < .01). Within each Cotton‐Myer grade, the intraclass correlation for % stenosis was 0.45 (P = .02) for grade I, 0.06 (P = .30) for grade II, and 0.16 (P = .03) for grade III. The intraclass correlation for PEF% for grade I was 0.97 (P < .01), grade II was 0.92 (P < .01), and grade III was 0.96 (P < .01).Conclusion: Cotton‐Myer grading and estimating percent obstruction (% stenosis) for adult subglottic stenosis showed poor reliability as an assessment tool compared to the excellent intraclass correlation seen with pulmonary function tests within each Cotton‐Myer grade subgroup. We recommend pulmonary function testing, specifically PEF% because it is a normalized value, for the assessment and management of subglottic stenosis.Level of evidence: 4.Keywords
Funding Information
- Massachusetts Eye and Ear
This publication has 22 references indexed in Scilit:
- Utility of Peak Inspiratory Flow in Managing Subglottic StenosisAnnals of Otology, Rhinology & Laryngology, 2014
- Using Pulmonary Function Data to Assess Outcomes in the Endoscopic Management of Subglottic StenosisAnnals of Otology, Rhinology & Laryngology, 2014
- Physiology‐based minimum clinically important difference thresholds in adult laryngotracheal stenosisThe Laryngoscope, 2014
- Subjective assessment using still bronchoscopic images misclassifies airway narrowing in laryngotracheal stenosisInteractive CardioVascular and Thoracic Surgery, 2013
- Morphometric bronchoscopy in adults with central airway obstruction: Case illustrations and review of the literatureThe Laryngoscope, 2009
- Influence of glottic aperture on the tracheal flowJournal of Biomechanics, 2007
- Early Endoscopic Treatment of Acute Inflammatory Airway Lesions Improves the Outcome of Postintubation Airway StenosisThe Laryngoscope, 2006
- Objective Sizing of Upper Airway Stenosis: A Quantitative Endoscopic ApproachThe Laryngoscope, 2006
- Proposed Grading System for Subglottic Stenosis Based on Endotracheal Tube SizesAnnals of Otology, Rhinology & Laryngology, 1994
- Pediatric laryngotracheal stenosisJournal of Pediatric Surgery, 1984