In vitro evaluation of a custom cutting jig and custom plate for canine tibial plateau leveling
Authors:
- Denis J. Marcellin-LittleDMDenis J. Marcellin-Little
- Ola L. A. HarryssonOHOla L. A. Harrysson
- Omer CansizogluOCOmer Cansizoglu
- 1 July 2008
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 69 (7) , 961-966
Abstract
Objective—To design and manufacture custom titanium bone plates and a custom cutting and drill guide by use of free-form fabrication methods and to compare variables and mechanical properties of 2 canine tibial plateau leveling methods with each other and with historical control values. Sample Population—10 canine tibial replicas created by rapid prototyping methods. Procedures—Application time, accuracy of correction of the tibial plateau slope (TPS), presence and magnitude of rotational and angular deformation, and replica axial stiffness for 2 chevron wedge osteotomy (CWO) methods were assessed. One involved use of freehand CWO (FHCWO) and screw hole drilling, whereas the other used jig-guided CWO (JGCWO) and screw hole drilling. Results—Replicas used for FHCWO and JGCWO methods had similar stiffness. Although JGCWO and FHCWO did not weaken the replicas, mean axial stiffness of replicas after JGCWO was higher than after FHCWO. The JGCWO method was faster than the FHCWO method. Mean ± SD TPS after osteotomy was lower for FHCWO (4.4 ± 1.1°) than for JGCWO (9.5 ± 0.4°), and JGCWO was more accurate (target TPS, 8.9°). Slight varus was evident after FHCWO but not after JGCWO. Mean postoperative rotation after JGCWO and FHCWO did not differ from the target value or between methods. Conclusions and Clinical Relevance—The JGCWO method was more accurate and more rapid and resulted in more stability than the FHCWO method. Use of custom drill guides could enhance the speed, accuracy, and stability of corrective osteotomies in dogs.Keywords
This publication has 33 references indexed in Scilit:
- Evaluation of Biocompatible Photopolymers II: Further Reactive DiluentsMonatshefte für Chemie - Chemical Monthly, 2007
- The Role of the High Tibial Osteotomy in the Unstable KneeSports Medicine and Arthroscopy Review, 2007
- Photopolymers for Rapid Prototyping of Soluble Mold Materials and Molding of Cellular BiomaterialsMonatshefte für Chemie - Chemical Monthly, 2006
- In vitro evaluation of five canine tibial plateau leveling methodsAmerican Journal of Veterinary Research, 2006
- Use of Stereolithographic Templates for Surgical and Prosthodontic Implant Planning and Placement. Part II. A Clinical ReportJournal of Prosthodontics, 2006
- Use of Stereolithographic Templates for Surgical and Prosthodontic Implant Planning and Placement. Part I. The ConceptJournal of Prosthodontics, 2006
- Computer assistance in total knee replacement – a critical assessment of current health care technologyComputer Aided Surgery, 2006
- Customized design and manufacturing of chin implant based on rapid prototypingRapid Prototyping Journal, 2005
- Improving accuracy of bone resections using robotics tool holder and a high speed milling cutting toolJournal of Medical Engineering & Technology, 1998
- Prospective, Randomized Comparison of Proximal Crescentic and Proximal Chevron Osteotomies for Correction of Hallux Valgus DeformityFoot & Ankle International, 1996