Validation of joint angle measurements: comparison of a novel low-cost marker-less system with an industry standard marker-based system
- 2 January 2019
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 43 (1) , 19-24
Abstract
Human motion tracking is widely used for the assessment of movement dysfunction in orthopaedic patients. Currently, most clinical motion analysis centres use marker-based three-dimensional (3D) systems as they are deemed to be the most accurate method. However, due to space, costs and logistics they are not available in many clinical settings. This study compared joint angles measured in functional tests using the novel low-cost Microsoft Kinect Perfect Phorm system with the established marker-based Nexus VICON system. When measuring right and left knee flexion, the average difference between the VICON and Kinect Perfect Phorm measurement was 13.2%, with a SD of 19.6. Both overestimation and underestimation of the joint angle was recorded in different participants. Although the average percentage difference during hip abduction tests was lower at −3.9%, the range of error was far greater (SD = 75). From this, it can be concluded that the level of accuracy presented in the new low-cost Kinect Perfect Phorm system is not yet suitable for clinical assessments. However, for general tests of performance, and for tracking cases where absolute accuracy is less critical, future versions of this software may have a place.Keywords
This publication has 9 references indexed in Scilit:
- Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysisJournal of Medical Engineering & Technology, 2014
- Validity and reliability of the Kinect within functional assessment activities: Comparison with standard stereophotogrammetryGait & Posture, 2014
- Biomechanical Validation of Upper-Body and Lower-Body Joint Movements of Kinect Motion Capture Data for Rehabilitation Treatments2012
- A Kinect-based system for physical rehabilitation: A pilot study for young adults with motor disabilitiesResearch in Developmental Disabilities, 2011
- A Preliminary Test of Measurement of Joint Angles and Stride Length with Wireless Inertial Sensors for Wearable Gait Evaluation SystemComputational Intelligence and Neuroscience, 2011
- The reliability of three-dimensional kinematic gait measurements: A systematic reviewGait & Posture, 2009
- Ankle and Knee Joint Angle Measurements during Gait with Wearable Sensor System for Rehabilitation2009
- Human motion tracking for rehabilitation—A surveyBiomedical Signal Processing and Control, 2008
- Defining the knee joint flexion–extension axis for purposes of quantitative gait analysis: An evaluation of methodsGait & Posture, 2006