Ion beam lithography: An investigation of resolution limits and sensitivities of ion-beam exposed PMMA

Authors:

Abstract
High resolution thin-membrane masks are duplicated in PMMA by contact printing with 250 keV Ga+ ions. Upon development, minimum feature widths on the order of 70 nm are obtained. Broadening of ion-exposed lines in PMMA as a function of development time is studied. A microscopic investigation of PMMA irradiated with 50 keV H+ ions and 250 keV Ga+ ions at doses near the development threshold reveals peculiar morphological modifications prior to, and following development. The modification of theoretical energy dissipation distributions with the inclusion of recoil atoms in heavy-ion irradiation of resists is investigated with the aid of a Monte Carlo simulation program (RECUL). Using the three-dimensional energy distributions thus obtained, developed-line profiles are simulated.