Abstract
We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance. We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in consensus then extracted information from primary articles relating to study characteristics and design, methods for reporting study outcomes, model fitting, model assumptions, presentation of results, and interpretation of findings. Results were summarized and presented with a descriptive analysis. Sixty-four full papers were retrieved from 475 identified citations and ultimately 49 articles describing 51 studies were reviewed and extracted. Radiological imaging was the index test in all. Most studies focused on lesion detection vs. characterization and used less than 10 readers. Only 6 (12%) studies trained readers in advance to use the confidence scale used to build the ROC curve. Overall, description of confidence scores, the ROC curve and its analysis was often incomplete. For example, 21 (41%) studies presented no ROC curve and only 3 (6%) described the distribution of confidence scores. Of 30 studies presenting curves, only 4 (13%) presented the data points underlying the curve, thereby allowing assessment of extrapolation. The mean change in AUC was 0.05 (−0.05 to 0.28). Non-significant change in AUC was attributed to underpowering rather than the diagnostic test failing to improve diagnostic accuracy. Data reporting in MRMC studies using ROC AUC as an outcome measure is frequently incomplete, hampering understanding of methods and the reliability of results and study conclusions. Authors using this analysis should be encouraged to provide a full description of their methods and results.Keywords
This publication has 92 references indexed in Scilit:
- Satisfaction of Search for Subtle Skeletal Fractures May Not Be Induced by More Serious Skeletal InjuryJournal of the American College of Radiology, 2012
- Increase in perceived case suspiciousness due to local contrast optimisation in digital screening mammographyEuropean Radiology, 2011
- Non-contrast Enhanced MRI for Evaluation of Breast LesionsAcademic Radiology, 2011
- Comparison Between Differently Priced Devices for Digital Capture of X-Ray Films Using Computed Tomography as a Gold Standard: A Multireader-Multicase Receiver Operating Characteristic Curve StudyTelemedicine and e-Health, 2011
- Effect of Computer-aided Detection for CT Colonography in a Multireader, Multicase TrialRadiology, 2010
- Breast cancer detection: radiologists’ performance using mammography with and without automated whole-breast ultrasoundEuropean Radiology, 2010
- Perceived Sufficiency of Full-Field Digital Mammograms With and Without Irreversible Image Data Compression for Comparison with Next-Year MammogramsJournal of Digital Imaging, 2010
- Presentation of Similar Images as a Reference for Distinction Between Benign and Malignant Masses on Mammograms: Analysis of Initial Observer StudyJournal of Digital Imaging, 2010
- Effect of Dose Reduction on the Ability of Digital Mammography to Detect Simulated MicrocalcificationsJournal of Digital Imaging, 2009
- Observer Study for Evaluating Potential Utility of a Super-High-Resolution LCD in the Detection of Clustered Microcalcifications on Digital MammogramsJournal of Digital Imaging, 2009