Relative Quantification: Characterization of Bias, Variability and Fold Changes in Mass Spectrometry Data from iTRAQ-Labeled Peptides
Authors:
- Douglas W. MahoneyDMDouglas W. Mahoney
- Terry M. TherneauTTTerry M. Therneau
- Carrie J. HeppelmannCHCarrie J. Heppelmann
- LeeAnn HigginsLHLeeAnn Higgins
- Linda M. BensonLBLinda M. Benson
- Roman M. ZenkaRZRoman M. Zenka
- Pratik JagtapPJPratik Jagtap
- Gary L. NelsestuenGNGary L. Nelsestuen
- H. Robert BergenHBH. Robert Bergen
- Ann L. ObergAOAnn L. Oberg
- 14 July 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 10 (9) , 4325-4333
Abstract
Shotgun proteomics via mass spectrometry (MS) is a powerful technology for biomarker discovery that has the potential to lead to noninvasive disease screening mechanisms. Successful application of MS-based proteomics technologies for biomarker discovery requires accurate expectations of bias, reproducibility, variance, and the true detectable differences in platforms chosen for analyses. Characterization of the variability inherent in MS assays is vital and should affect interpretation of measurements of observed differences in biological samples. Here we describe observed biases, variance structure, and the ability to detect known differences in spike-in data sets for which true relative abundance among defined samples were known and were subsequently measured with the iTRAQ technology on two MS platforms. Global biases were observed within these data sets. Measured variability was a function of mean abundance. Fold changes were biased toward the null and variance of a fold change was a function of protein mass and abundance. The information presented herein will be valuable for experimental design and analysis of the resulting data.Keywords
This publication has 36 references indexed in Scilit:
- Addressing Accuracy and Precision Issues in iTRAQ QuantitationMolecular & Cellular Proteomics, 2010
- A comparison of the accuracy of iTRAQ quantification by nLC-ESI MSMS and nLC-MALDI MSMS methodsJournal of Proteomics, 2010
- Temporal Stability of the Urinary Proteome after Kidney Transplant: More Sensitive than Protein Composition?Journal of Proteome Research, 2008
- Robust and Sensitive iTRAQ Quantification on an LTQ Orbitrap Mass SpectrometerMolecular & Cellular Proteomics, 2008
- Halobacterium salinarum NRC-1 PeptideAtlas: Toward Strategies for Targeted Proteomics and Improved Proteome CoverageJournal of Proteome Research, 2008
- A Statistical Model for iTRAQ Data AnalysisJournal of Proteome Research, 2008
- Eight-channel iTRAQ Enables Comparison of the Activity of Six Leukemogenic Tyrosine KinasesMolecular & Cellular Proteomics, 2008
- Statistical Analysis of Relative Labeled Mass Spectrometry Data from Complex Samples Using ANOVAJournal of Proteome Research, 2008
- Multiplexed Protein Quantitation in Saccharomyces cerevisiae Using Amine-reactive Isobaric Tagging ReagentsMolecular & Cellular Proteomics, 2004
- Empirical Statistical Model To Estimate the Accuracy of Peptide Identifications Made by MS/MS and Database SearchAnalytical Chemistry, 2002