The effect of force, timing, and location on bone-to-implant contact of miniscrew implants
Authors:
Open Access
- 10 December 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 31 (3) , 232-240
Abstract
This study was conducted to evaluate the effect of timing and force of loading, as well as implant location, on bone-to-implant contact (BIC) of loaded and control miniscrew implants (MSI). Using seven skeletally mature male beagle dogs, 1–2 years of age, followed over a 110 day period, a randomized split-mouth design compared immediate versus delayed loading, 50 versus 25 g loading, and 25 g loads in the maxilla versus the mandible. Mobility was evaluated using a 0–3 point scale before the MSIs were prepared for histological analysis. Histomorphometric analyses were performed under light microscopy using Metamorph® software on undecalcified sections. The percentage BIC was measured at three levels (coronal, middle, and apical) of the MSI. BIC was compared statistically using pairwise Wilcoxon signed-rank tests. Mobility was detected in three of the 56 (5.4 per cent) MSIs. The mobile implants were all unloaded controls and showed no BIC. All remaining stable MSIs showed some BIC. However, variation in BIC was large, ranging from 2.2 to 100 per cent. There were no significant (P > 0.05) differences in BIC associated with timing of force application, amount of force applied, or implant location. There was a tendency for less BIC at the coronal level, but the differences between levels were not statistically significant. Within the limits of this study, it is concluded that the timing and amount of force at loading and location of implant placement do not affect BIC. Moreover, it appears that only limited amounts of osseointegration are necessary to ensure implant stability.Keywords
This publication has 39 references indexed in Scilit:
- Segmental intrusion with mini-screw implant anchorage: A radiographic evaluationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Experimental evaluation of tooth movement in the beagle dog with the mini-screw implant for orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2007
- Focal hyalinization during experimental tooth movement in beagle dogsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- Peri‐Implant Soft Tissue Integration of Immediately Loaded Implants in the Posterior Macaque Mandible: A Histomorphometric StudyJournal of Periodontology, 2003
- Immediate and Early Function of Brånemark System® Implants Placed in the Esthetic Zone: A 1‐Year Prospective Clinical Multicenter StudyClinical Implant Dentistry and Related Research, 2003
- The use of an osseointegrated implant for orthodontic anchorage to a class II Div 1 malocclusion.The Bulletin of Tokyo Dental College, 2001
- Tooth movement with light continuous and discontinuous forces in beagle dogsEuropean Journal of Oral Sciences, 1999
- Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit.Clinical Oral Implants Research, 1997
- Magnitude of orthodontic forces and rate of bodily tooth movement. An experimental studyAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1996
- Tooth mobility and periodontal therapyJournal of Clinical Periodontology, 1980