Application of 3-D Δ Check Graphs to HbA1cQuality Control and HbA1cUtilization
Authors:
Open Access
- 1 August 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 130 (2) , 292-298
Abstract
Δ checking is a laboratory information system (LIS)-based tool that detects patient and laboratory quality control errors. By using hemoglobin A1c (HbA1c) data, we developed a novel approach to summarizing and presenting patient Δ values to address limitations of current Δ check algorithms. Δ values were calculated from intrapatient pairs of (n = 55,327) measured during 2 years in a single HbA1c referral or a university hospital laboratory. Three-dimensional Δ -time (Δ T) and percentile limit graphs were constructed. Cumulative distribution function analysis was used to explore clinical utilization. The Δ values T graphs showed that HbA1c increase asymmetrically over time. Although the 2.5 to 97.5 and 5.0 to 95.0 percentile Δ check limits were similar for both sites, the referral laboratory’s 0.5 to 99.5 percentile limits were wider. For acute patient care environments, we recommend limits of –3.5% and 1.8% for measurements between 0 and 60 days and –4.0% and 2.0% for measurements between 60 and 120 days. For the outpatient environment, we recommend limits of –4.2% and 2.1% and 5.0% and 2.5% for measurements between 0 and 60 days and 60 and 120 days, respectively. Δ checking can be significantly improved with customization of limits set by population and interobservation period. Because LIS systems are incapable of these customizations, customers must become advocates for these modifications.Keywords
This publication has 15 references indexed in Scilit:
- QA aspects for HbA1c measurementsClinical Biochemistry, 2007
- Errors in a Stat Laboratory: Types and Frequencies 10 Years LaterClinical Chemistry, 2007
- Malignant Hyperthermia Following Systemic Rewarming After Hypothermic Cardiopulmonary BypassAnesthesia & Analgesia, 2006
- Monitoring glycemic control: the importance of self-monitoring of blood glucoseThe American Journal of Medicine, 2005
- Postanalytical External Quality Assessment of Blood Glucose and Hemoglobin A1c: An International SurveyClinical Chemistry, 2005
- Standards of medical care in diabetes2005
- Quality specification in haematology: the automated blood cell countClinica Chimica Acta, 2004
- Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes MellitusClinical Chemistry, 2002
- Defining the Relationship Between Plasma Glucose and HbA1cDiabetes Care, 2002
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998