Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study
Open Access
- 3 September 2015
- journal article
- research article
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 62 (11) , 1153-1160
Abstract
Background Pulse pressure variation (PPV) and stroke volume variation (SVV) are dynamic preload variables that can be measured noninvasively to assess fluid responsiveness (FR) in anesthetized patients with mechanical ventilation. Few studies have examined the effectiveness of predicting FR according to the definition of FR, and assessment of inconclusive values of PPV and SVV around the cut-off value (the “grey zone”) might improve individual FR prediction. We explored the ability of noninvasive volume clamp derived measurements of PPV and SVV to predict FR using the grey zone approach, and we assessed the influence of multiple thresholds on the predictive ability of the numerical definition of FR. Methods Ninety patients undergoing general surgery were included in this prospective observational study and received a 500 mL fluid bolus as deemed clinically required by the attending anesthesiologist. A minimal relative increase in stroke volume index (↑SVI) was used to define FR with different thresholds from 10-25%. The PPV, SVV, and SVI were measured using the Nexfin® device that employs noninvasive volume clamp plethysmography. Results The area under the receiver operator characteristic curve gradually increased for PPV / SVV with higher threshold values (from 0.818 / 0.760 at 10% ↑SVI to 0.928 / 0.944 at 25% ↑SVI). The grey zone limits of both PPV and SVV changed from 9–16% (PPV) and 5–13% (SVV) at the 10% ↑SVI threshold to 18–21% (PPV) and 14–16% (SVV) at the 25% ↑SVI threshold. Conclusion Noninvasive PPV and SVV measurements allow an acceptable FR prediction, although the reliability of both variables is dependent on the intended increase in SVI, which improves substantially with concomitant smaller grey zones at higher ↑SVI thresholds.Keywords
This publication has 31 references indexed in Scilit:
- Noninvasive Continuous Cardiac Output by the Nexfin Before and After Preload-Modifying ManeuversAnesthesia & Analgesia, 2013
- Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indicesBritish Journal of Anaesthesia, 2012
- Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal DopplerJournal of Clinical Anesthesia, 2012
- Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®Anesthesiology, 2012
- A comparison of the Nexfin ® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgeryAnaesthesia, 2012
- Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid ResponsivenessAnesthesiology, 2011
- A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac OutputAnesthesia & Analgesia, 2010
- The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgeryAnaesthesia, 2010
- Statistical Evaluation of a BiomarkerAnesthesiology, 2010
- Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patientsBMC Anesthesiology, 2009