Abstract
A flexible, patch-type strain sensor is described for continuous monitoring of pulse waves. The proposed sensor exploits the piezo-resistivity of the conductive polymer, polyaniline (PANI), to detect dynamic volume changes in blood vessels owing to pulse waves. The proposed PANI film was fabricated through electrodeposition, which is considered as a suitable low-cost technique for mass production in the sensor manufacturing industry. Thus, it is prospective for a disposable wearable sensing system solution in remote healthcare applications. Besides, a flexible sensor packaging can be achieved by laminating the PANI films and an ECOFLEX elastomer to the film bandage. The proposed PANI sensor has high sensitivity (gauge factor of 74.28) and linearity (R2 = 0.99). It also showed a high correlation with commercially available photoplethysmography (PPG) sensor with the small bias and confidence interval to the PPG sensor: bias < 0.1% and confidence interval < 3% for all subjects. Moreover, the proposed PANI sensor was tested for prospective circulatory system-related applications such as measuring heart rate, stiffness index, and pulse transit time. Finally, the proposed study suggests that the proposed PANI sensor is a promising candidate for continuous, long-term, unobtrusive pulse wave monitoring, which can provide real-time insights into an individual’s health status.Keywords
Funding Information
- National Research Foundation of Korea
- Korea Government Ministry of Science and ICT (NRF-2017R1A5A1015596, 2020R1A2C2005385)
- Technology Innovation Program (or Industrial Strategic Technology Development Program)
- Ministry of Trade, Industry and Energy (MOTIE), South Korea (20001841)
This publication has 52 references indexed in Scilit:
- A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising?IRBM, 2014
- Electropolymerization of polyaniline thin filmsHigh Performance Polymers, 2014
- Highly Stretchable Resistive Pressure Sensors Using a Conductive Elastomeric Composite on a Micropyramid ArrayAdvanced Materials, 2014
- Flexible and Stretchable Electronics for Biointegrated DevicesAnnual Review of Biomedical Engineering, 2012
- Pulse wave velocity as a diagnostic Index: The pitfalls of tethering versus stiffening of the arterial wallJournal of Biomechanics, 2011
- Pulse Wave Analysis of the Aortic Pressure Waveform in Severe Left Ventricular Systolic DysfunctionCirculation: Heart Failure, 2010
- Arterial blood pressure measurement and pulse wave analysis-–their role in enhancing cardiovascular assessmentPhysiological Measurement, 2009
- Studies on the resonance Raman spectra of polyaniline obtained with near‐IR excitationJournal of Raman Spectroscopy, 2007
- Is augmentation index a good measure of vascular stiffness in the elderly?Age and Ageing, 2006
- Arterial stiffness assessed by pulse wave analysis in essential hypertension: relation to 24-h blood pressure profileInternational Journal of Cardiology, 2005