Intravital microscopic observation of the microvasculature during hemodialysis in healthy rats
Open Access
- 7 January 2022
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
Abstract
Hemodialysis (HD) provides life-saving treatment for kidney failure. Patient mortality is extremely high, with cardiovascular disease (CVD) being the leading cause of death. This results from both a high underlying burden of cardiovascular disease, as well as additional physiological stress from the HD procedure itself. Clinical observations indicate that HD is associated with microvascular dysfunction (MD), underlining the need for a fundamental pathophysiological assessment of the microcirculatory consequences of HD. We therefore successfully developed an experimental small animal model, that allows for a simultaneous real-time assessment of the microvasculature. Using in-house built ultra-low surface area dialyzers and miniaturized extracorporeal circuit, we successfully dialyzed male Wistar Kyoto rats and combined this with a simultaneous intravital microscopic observation of the EDL microvasculature. Our results show that even in healthy animals, a euvolemic HD procedure can induce a significant systemic hemodynamic disturbance and induce disruption of microvascular perfusion (as evidence by a reduction in the proportion of the observed microcirculation receiving blood flow). This study, using a new small animal hemodialysis model, has allowed direct demonstration that microvascular blood flow in tissue in skeletal muscle is acutely reduced during HD, potentially in concert with other microvascular beds. It shows that preclinical small animal models can be used to further investigate HD-induced ischemic organ injury and allow rapid throughput of putative interventions directed at reducing HD-induced multi-organ ischemic injury.Keywords
Funding Information
- Lawson Health Research Institute (IRF20-18)
This publication has 81 references indexed in Scilit:
- Detection of microcirculatory impairment by transcutaneous oxymetry monitoring during hemodialysis: an observational studyBMC Nephrology, 2014
- Establishment of a Blood Purification System for Renal Failure Rats Using Small‐Size Dialyzer MembranesTherapeutic Apheresis and Dialysis, 2012
- Impaired microvascular perfusion in sepsis requires activated coagulation and P-selectin-mediated platelet adhesion in capillariesIntensive Care Medicine, 2010
- Pediatric Myocardial Stunning Underscores the Cardiac Toxicity of Conventional Hemodialysis TreatmentsClinical Journal of the American Society of Nephrology, 2009
- Central venous oxygen saturation and thoracic admittance during dialysis: New approaches to hemodynamic monitoringHemodialysis International, 2008
- Silent Myocardial Ischemia and High-Grade Ventricular Arrhythmias in Patients on Maintenance HemodialysisRenal Failure, 2005
- In vivo visualization of hemodialysis-induced alterations in leukocyte–endothelial interactionsKidney International, 2000
- Experimental Hypocalcemia Induced by Hemodialysis in Goats.Journal of Veterinary Medical Science, 1999
- Heparin-Free Hypothermal Hemodialysis at 20°C Improves BiocompatibilityBlood Purification, 1997
- Effect of blood cooling on cuprophan-induced anaphylatoxin generationKidney International, 1987