Ex vivo Comparison of Handheld Myotonometry and Tensile Deformation in Porcine Patellar Tendons
Open Access
- 7 November 2026
- journal article
- Published by Scientific Scholar
- Vol. 80, 39-45
Abstract
Objectives: Patellar tendon (PT) stiffness is relevant for understanding tendon loading, adaptation, and mechanical changes. However, objective tools for assessing PT stiffness are limited in clinical settings. Myoton PRO is a handheld device used for regional oscillation-based stiffness measurement; however, the association between Myoton PRO and a tensile testing machine for the PT remains unclear. This ex vivo study aimed to examine the association between regional dynamic stiffness measured using the Myoton PRO and structural stiffness measured using tensile testing in porcine PTs. Material and Methods: Twenty-eight fresh porcine knees were included in this ex vivo experimental study. The primary outcome was the correlation between regional dynamic stiffness measured using the Myoton PRO and structural stiffness measured using tensile testing. Dynamic stiffness was measured at the PT proximal (PT-p), central (PT-c), and distal (PT-d) sites using the Myoton PRO. The structural stiffness was measured using a tensile testing machine. The correlations between dynamic and structural stiffness were analyzed using Pearson’s correlation coefficients, and intra-rater reliability was evaluated using the intraclass correlation coefficient (ICC). Results: The dynamic stiffness measured using the Myoton PRO was as follows: 911.3 ± 129.5 N/m at PT-p, 875.9 ± 183.3 N/m at PT-c, and 930.3 ± 136.0 N/m at PT-d. The structural stiffness was 38.2 ± 9.6 N/mm. Dynamic stiffness showed moderate positive correlations with structural stiffness at PT-p (r = 0.46, 95% CI 0.11-0.71, p = 0.013), PT-c (r = 0.57, 95% CI 0.25-0.77, p = 0.002), and PT-d (r = 0.44, 95% CI 0.08-0.70, p = 0.020). The intra- rater reliability was satisfactory at all sites, with ICC (1,3) values ranging from 0.98 to 0.99. Conclusion: Myoton PRO measurements were highly reproducible and moderately correlated with structural stiffness measured using tensile testing under ex vivo conditions. Interpretation is limited by the use of healthy ex vivo porcine specimens, the absence of direct human validation, and the evaluation of structural rather than intrinsic material stiffness. These findings provide preliminary biomechanical evidence supporting further investigation of regional myotonometry in pathological and in vivo tendon models.Keywords
This publication has 40 references indexed in Scilit:
- Changes in patellar tendon stiffness and mechanical strength test using collagenase injection: Verification ex vivo experiment using porcine modelClinical Biomechanics, 2025
- Shear-wave elastography for the evaluation of tendinopathies: a systematic review and meta-analysisLa radiologia medica, 2023
- A review on the use of porcine in tendon researchAnnals of Anatomy - Anatomischer Anzeiger, 2023
- Material Properties of Suture Augmentation of Knee Medial Collateral Ligament Repair Did Not Influence Length Changes or Failure Loads in a Caged Porcine ModelArthroscopy, Sports Medicine, and Rehabilitation, 2023
- The association between patellar tendon stiffness measured with shear-wave elastography and patellar tendinopathy—a case-control studyEuropean Radiology, 2020
- Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injuryInsights into Imaging, 2018
- Characterization of tissue stiffness of the infraspinatus, erector spinae, and gastrocnemius muscle using ultrasound shear wave elastography and superficial mechanical deformationJournal of Electromyography and Kinesiology, 2018
- Critical review on the socio-economic impact of tendinopathyAsia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 2016
- Feasibility of monitoring muscle health in microgravity environments using Myoton technologyMedical & Biological Engineering & Computing, 2014
- Tendon properties and muscle architecture for knee extensors and plantar flexors in boys and menClinical Biomechanics, 2014