Poor Correlation of Rivaroxaban Concentration with the Routine Coagulation Screening Test in Chinese Patients with Atrial Fibrillation
Open Access
- 1 January 2023
- journal article
- research article
- Published by Wiley in Journal of Clinical Pharmacy and Therapeutics
- Vol. 2023 (1)
Abstract
Aims. The aim of this study is to assess the relationship between rivaroxaban plasma concentration quantified by the gold standard and anticoagulant activities measured by routine coagulation assays in Chinese atrial fibrillation (AF) patients. Whether the normal results of these tests were reliable to rule out clinically relevant rivaroxaban levels at various thresholds was also explored. The effect of clinical drug‐drug interactions (DDIs) on the exposure and anticoagulant effect of rivaroxaban were further evaluated. Methods. 116 patients receiving rivaroxaban for the management of nonvalvular AF were recruited. Rivaroxaban concentrations and coagulation tests were measured by ultra‐performance liquid chromatography‐tandem mass spectrometry (UPLC‐MS/MS) and a blood coagulation analyzer, respectively. Results. The correlation of trough concentration (Ctrough) and prothrombin time (PT) or international normalized ratio (INR) was moderate with Spearman’s correlation coefficient of 0.495 and 0.506, respectively. A normal PT/INR was unable to rule out Ctrough levels of >30 ng/mL and >50 ng/mL, but the negative predictive value reached 100% to exclude Ctrough of >100 ng/mL. Ctrough showed a small correlation with activated partial thromboplastin time (aPTT) (Spearman’s correlation coefficient: 0.241) and no correlation with thrombin time (TT) (Spearman’s correlation coefficient: 0.074). Neither aPTT nor TT accurately predicted Ctrough at any concentration. Peak concentration (Cpeak) did not correlate with any coagulation parameters. The presence of digoxin and febuxostat significantly increased rivaroxaban Ctrough by 2.18 fold and prolonged PT and INR by 44.16% and 43.60%, respectively. Conclusions. Normal routine coagulation assays were insufficient to monitor therapy with rivaroxaban. Poor correlations between rivaroxaban concentration and routine coagulation assays were observed in Chinese AF patients. The use of digoxin/febuxostat alone had no effect on rivaroxaban concentrations; however, combined strong breast cancer resistance protein inhibitor (febuxostat) and P‐glycoprotein probe (digoxin) in patients with renal impairment is likely to cause clinically significant DDI with rivaroxaban. More studies are needed to establish routine therapeutic drug monitoring of rivaroxaban in clinical practice.Keywords
Funding Information
- National Natural Science Foundation of China (82160707)
- Natural Science Foundation of Jiangxi Province (20202ACB216005)
- Postdoctoral Science Foundation of Jiangxi Province (2017KY24)
This publication has 44 references indexed in Scilit:
- Laboratory Measurement of the Anticoagulant Activity of the Non–Vitamin K Oral AnticoagulantsJACC, 2014
- Population pharmacokinetics and pharmacodynamics of rivaroxaban in patients with non‐valvular atrial fibrillation: Results from ROCKET AFThe Journal of Clinical Pharmacology, 2014
- Clinical Pharmacokinetic and Pharmacodynamic Profile of RivaroxabanClinical Pharmacokinetics, 2013
- Management of major bleeding complications and emergency surgery in patients on long-term treatment with direct oral anticoagulants, thrombin or factor-Xa inhibitors: Proposals of the Working Group on Perioperative Haemostasis (GIHP) – March 2013Archives of Cardiovascular Diseases, 2013
- Recommendations for the emergency management of complications associated with the new direct oral anticoagulants (DOACs), apixaban, dabigatran and rivaroxabanClinical Research in Cardiology, 2013
- RivaroxabanClinical Pharmacokinetics, 2011
- Assays for Measuring Rivaroxaban: Their Suitability and LimitationsTherapeutic Drug Monitoring, 2010
- Safety, pharmacokinetics and pharmacodynamics of single/multiple doses of the oral, direct Factor Xa inhibitor rivaroxaban in healthy Chinese subjectsBritish Journal of Clinical Pharmacology, 2009
- Body Weight Has Limited Influence on the Safety, Tolerability, Pharmacokinetics, or Pharmacodynamics of Rivaroxaban (BAY 59‐7939) in Healthy SubjectsThe Journal of Clinical Pharmacology, 2007
- In vitro and in vivo studies of the novel antithrombotic agent BAY 59-7939—an oral, direct Factor Xa inhibitorJournal of Thrombosis and Haemostasis, 2005