Longitudinal and multi‐echo transverse relaxation times of normal breast tissue at 3 Tesla
Open Access
- 29 September 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 32 (4) , 982-987
Abstract
Purpose: To measure longitudinal (T1) and multi‐echo transverse (T2) relaxation times of healthy breast tissue at 3 Tesla (T).Materials and Methods: High‐resolution relaxation time measurements were made in six healthy female subjects. Inversion recovery images were acquired at 10 inversion times between 100 ms and 4000 ms, and multiple spin echo images were acquired at 16 echo times between 10 ms and 160 ms.Results: Longitudinal relaxation times T1 were measured as 423 ± 12 ms for adipose tissue and 1680 ± 180 ms for fibroglandular tissue. Multi‐echo transverse relaxation times T2 were measured as 154 ± 9 ms for adipose tissue and 71 ± 6 ms for fibroglandular tissue. Histograms of the voxel‐wise relaxation times and quantitative relaxation time maps are also presented.Conclusion: T1 and multi‐echo T2 relaxation times in normal human breast tissue are reported. These values are useful for pulse sequence design and optimization for 3T breast MRI. Compared with the literature, T1 values are significantly longer at 3T, suggesting that longer repetition time and inversion time values should be used for similar image contrast. J. Magn. Reson. Imaging 2010;32:982–987.Keywords
This publication has 24 references indexed in Scilit:
- MRI-guided vacuum-assisted breast biopsy: A phantom and patient evaluation of targeting accuracyJournal of Magnetic Resonance Imaging, 2009
- Multiparametric Magnetic Resonance Imaging of Breast CancerJournal of the American College of Radiology, 2009
- The utility of MRI for the screening and staging of breast cancerInternational Journal Of Clinical Practice, 2008
- MRI Evaluation of the Contralateral Breast in Women with Recently Diagnosed Breast CancerNew England Journal of Medicine, 2007
- Relaxation times of breast tissue at 1.5T and 3T measured using IDEALJournal of Magnetic Resonance Imaging, 2005
- MRI detection of distinct incidental cancer in women with primary breast cancer studied in IBMC 6883Journal of Surgical Oncology, 2005
- Why fat is bright in rare and fast spin‐echo imagingJournal of Magnetic Resonance Imaging, 1992
- Factors influencing contrast in fast spin-echo MR imagingMagnetic Resonance Imaging, 1992
- Benign and malignant breast disease: magnetic resonance and radiofrequency pulse sequencesAmerican Journal of Roentgenology, 1985
- A new look at the statistical model identificationIEEE Transactions on Automatic Control, 1974