The role of Cu in the time dependent dielectric breakdown (TDDB) performance of Cu/low-k integrated systems was studied. Interdigitated comb capacitors with and without Cu incorporated in the structure were temperature bias stressed (BTS). The Cu containing structures failed in a fraction of the time of the Cu-free samples. Annealing for 1200+ hours without bias did not change the failure times as compared to a 5 minute anneal, indicating that diffusion of neutral Cu does not play a role in TDDB. The results can be attributed to field enhanced Cu diffusion in the framework of an "impact damage" TDDB failure modelKeywords
This publication has 3 references indexed in Scilit:
- Effect of Cu Migration in a Field Induced Dielectric FailureMRS Proceedings, 2006
- Simple model for time-dependent dielectric breakdown in inter- and intralevel low-k dielectricsJournal of Applied Physics, 2005
- Time dependent dielectric breakdown in a low-k interlevel dielectricMicroelectronics Reliability, 2004