A New Sensor Technology for 2D Ultrasound-Guided Needle Tracking
Authors:
- 1 January 2014
- book chapter
- Published by Springer Nature
- Vol. 17, 389-396
Abstract
2D Ultrasound (US) is becoming the preferred modality for image-guided interventions due to its low cost and portability. However, the main limitation is the limited visibility of surgical tools. We present a new sensor technology that can easily be embedded on needles that are used for US-guided interventions. Two different types of materials are proposed to be used as sensor - co-polymer and PZT. The co-polymer technology is particularly attractive due to its plasticity, allowing very thin depositions (10-20 μm) on a variety of needle shapes. Both sensors receive acoustic energy and convert it to an electrical signal. The precise location of the needle can then be estimated from this signal, to provide real-time feedback to the clinician. We evaluated the feasibility of this new technology using (i) a 4DOF robot in a water tank; (ii) extensive ex vivo experiments; and (iii) in vivo studies. Quantitative robotic studies indicated that the co-polymer is more robust and stable when compared to PZT. In quantitative experiments, the technology achieved a tracking accuracy of 0.14 ± 0.03mm, significantly superior to competing technologies. The technology also proved success in near-real clinical studies on tissue data. This sensor technology is non-disruptive of existing clinical workflows, highly accurate, and is cost-effective. Initial clinician feedback shows great potential for large scale clinical impact.Keywords
This publication has 8 references indexed in Scilit:
- A Non-disruptive Technology for Robust 3D Tool Tracking for Ultrasound-Guided InterventionsLecture Notes in Computer Science, 2011
- Enhancement of needle visibility in ultrasound-guided percutaneous proceduresUltrasound in Medicine & Biology, 2004
- Changes in Ultrasonographic Echogenicity and Visibility of Needles with Changes in Angles of InsonationJournal of Vascular and Interventional Radiology, 2003
- Echocardiographic Transponder-Guided Catheter Ablation Feasibility and AccuracyJournal of Interventional Cardiac Electrophysiology, 2001
- Locating a catheter transducer in a three-dimensional ultrasound imaging fieldIEEE Transactions on Biomedical Engineering, 2001
- A system for ultrasonic beacon-guidance of catheters and other minimally-invasive medical devicesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- A new electronically enhanced biopsy system: value in improving needle-tip visibility during sonographically guided interventional procedures.American Journal of Roentgenology, 1992
- Use of an acoustic transponder for US visualization of biopsy needles.Radiology, 1991