Evaluation of scatter dose of dental titanium implants exposed to photon beams of different energies and irradiation angles in head and neck radiotherapy
Authors:
- M BeyzadeogluMBM Beyzadeoglu
- B DiricanBDB Dirican
- K OysulKOK Oysul
- J OzenJOJ Ozen
- O UcokOUO Ucok
- 1 January 2006
- journal article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 35 (1) , 14-17
Abstract
In this study, quantification of backscatter doses between scattering titanium dental implant and the thermoluminescent dosimeter (TLD(100)) radiation detector at axial beam irradiation-angle range of 0-90 degrees in head and neck radiotherapy is done to evaluate irradiation angle dependency of dose enhancement contributing to osteoradionecrosis. A cylindrical titanium dental implant with diameter of 4 mm and length of 9 mm was implanted into a specially-designed human mandible phantom with a TLD100 chip placed on the buccal site and irradiated with 6 MV X, 25 MV X and Co-60 gamma sources at 19 different irradiation angles. Dose enhancement on a buccal site of the titanium implant depends on the incident beam angle. At angles of 65 degrees, 60 degrees and 40 degrees the maximum detected scatter doses over the titanium implant are 36%, 32% and 23% for Co-60 gamma, 6 MV X-ray and 25 MV X-ray, respectively. The dose enhancement at different beam angles was less pronounced in 25 MV X and more pronounced in Co-60 gamma irradiation. For the different radiation beams studied, the irradiation angle between scattering titanium dental implants and the central axis does not significantly affect the total dose that may lead to osteoradionecrosis of the mandible.Keywords
This publication has 18 references indexed in Scilit:
- Dosimetric evaluation of the effect of dental implants in head and neck radiotherapyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2005
- A Clinical Evaluation of Implants in Irradiated Oral Cancer PatientsJournal of Dental Research, 2002
- Conservative management of osteoradionecrosisOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1997
- Osteoradionecrosis of the jaws: A retrospective study of the background factors and treatment in 104 casesJournal of Oral and Maxillofacial Surgery, 1997
- In vitro backscattering from implant materials during radiotherapyThe Journal of Prosthetic Dentistry, 1996
- Postradiation dental extractions without hyperbaric oxygenOral Surgery, Oral Medicine, Oral Pathology, 1991
- Titanium: The mystery metal of implant dentistry. Dental materials aspectsThe Journal of Prosthetic Dentistry, 1985
- Osteoradionecrosis: Predisposing factors and outcomes of therapyHead & Neck Surgery, 1984
- The edentulous milieuThe Journal of Prosthetic Dentistry, 1983
- Back-scattering from metals in superficial therapy with high energy electronsBritish Journal of Radiology, 1974