Rapid screening of plasma volume expanders in urine using matrix‐assisted laser desorption/ionisation time‐of‐flight mass spectrometry
- 17 May 2004
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 18 (12) , 1324-1330
Abstract
The use of plasma volume expanders, especially those based on chemically modified polysaccharides such as hydroxyethyl starch, has found its way from the medical field to the athletic community in the everlasting drive for performance enhancement. As such, plasma volume expanders have been placed on the list of banned substances by the International Olympic Committee, and in turn require accurate and sensitive analytical tools for their detection in complex biological matrices. Here we present a relatively straightforward method for the detection of polysaccharide‐based plasma volume expanders (PVE) in urine, based on the carefully controlled partial acid hydrolysis of urine (20 μL) in a total volume of 500 μL 4 M trifluoroacetic acid. Following the incubation (30 min at 100°C) an aliquot of the hydrolysate is dried, re‐suspended in the analytical matrix (e.g. 2,5‐dihydroxybenzoic acid) and examined by matrix‐assisted laser desorption/ionisation time‐of‐flight mass spectrometry (MALDI‐TOFMS). The obtained mass spectrometric profile reveals a high number of characteristic peaks in the mass range between 500 and 3000 Da, a region that in urine samples devoid of PVE appears relatively clean, and thus allows the unambiguous identification of the presence of such PVE. This approach is fast (the mass profile can be obtained within 90 min), highly sensitive (the effective sample amount on the MALDI target is equivalent to 100 nL urine), needs little sample handling (four steps), requires no derivatisation and is devoid of interference from other biomolecules. The approach has been worked‐out for hydroxy ethyl starch but can be applied to other polymer‐derived plasma expanders such as dextran and probably the newly developed acetyl starch. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 12 references indexed in Scilit:
- Analysis of a bioactive β ‐(1 → 3) polysaccharide ( Curdlan ) using matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2003
- Evaluation of a new multiple‐layer spotting technique for matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry of synthetic polymersRapid Communications in Mass Spectrometry, 2003
- Thrombelastographische Gerinnungsanalyse nach in-vitro- und in-vivo-Hämodilution mit Hydroxyethylstärke (HES)AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 2002
- Hydroxyethyl Starch in Balanced Electrolyte Solution (Hextend®)—Pharmacokinetic and Pharmacodynamic Profiles in Healthy VolunteersAnesthesia & Analgesia, 2002
- Long-term follow-up of transplanted kidneys according to plasma volume expander of kidney donorsIntensive Care Medicine, 2001
- Pharmacodynamics and tolerability of acetyl starch as a new plasma volume expander in patients undergoing elective surgeryInt. Journal of Clinical Pharmacology and Therapeutics, 2000
- Detection of the plasma volume expander hydroxyethyl starch in human urineJournal of Chromatography B: Biomedical Sciences and Applications, 2000
- Mass spectrometry of partially methylated alditol acetates derived from hydroxyethyl starchJournal of Mass Spectrometry, 2000
- Hetastarch: An Overview of the Colloid and its MetabolismDrug Intelligence & Clinical Pharmacy, 1983
- Hemodynamic, blood volume, and oxygen transport responses to albumin and hydroxyethyl starch infusions in critically ill postoperative patientsCritical Care Medicine, 1980