Axillary and Rectal Temperature Measurements Poorly Agree in Newborn Infants
Authors:
- P.C.E. Hissink MullerPMP.C.E. Hissink Muller
- L.H. van BerkelLBL.H. van Berkel
- A.J. de BeaufortABA.J. de Beaufort
- 4 January 2008
- journal article
- research article
- Published by S. Karger AG in Neonatology
- Vol. 94 (1) , 31-34
Abstract
Aim: Evaluation of the agreement between axillary temperature measurements and rectal temperature measurements in neonates. Methods: Rectal and axillary body temperatures were simultaneously measured for 3 min in 33 neonates (gestational age 25–42 weeks, weight 840–4,005 g). Two investigators performed paired measurements, one in each neonate. A single type of thermometer was used in this study: one thermometer for each rectal and another thermometer for each axillary measurement. The Bland-Altman method was used (95% ‘limits of agreement’: mean ± 2 SD) to determine the level of agreement between axillary and rectal measurements. Results: The axillary temperature was significantly lower than the rectal temperature (mean ± SD 0.27 ± 0.20°C, p < 0.05). The ‘95% limits of agreement’ ranged from –0.13 to +0.67°C. Increasing postnatal age (days) showed a significant increase in temperature difference (rectal minus axillary; r = 0.54; p < 0.05). Conclusions: The mean difference between axillary and rectal temperature shows a wide variation. Axillary temperature measurements cannot be used interchangeably with rectal measurements in neonates.Keywords
This publication has 24 references indexed in Scilit:
- Evaluation of a New Thermometer for Rapid Axillary Temperature Measurement in Preterm InfantsAmerican Journal of Perinatology, 2003
- Effects of visible-light irradiation on vitreous structure in the presence of a photosensitizerExperimental Eye Research, 1987
- OUTBREAK OF SALMONELLA EIMSBUETTEL IN NEWBORN INFANTS SPREAD BY RECTAL THERMOMETERSThe Lancet, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Salmonella cross-infection associated with contamination of rectal thermometersJournal of Hospital Infection, 1981
- Heat balance in premature infants: Comparative effects of convectively heated incubator and radiant warmer, with and without plastic heat shieldThe Journal of Pediatrics, 1980
- Water loss from the skin of term and preterm babies.Archives of Disease in Childhood, 1979
- RECTAL PERFORATION BY THERMOMETERThe Lancet, 1969
- A controlled study of the effect of temperature on premature babiesThe Journal of Pediatrics, 1962
- Neutral Temperature Range and Range of “Thermal Comfort” in Premature InfantsNeonatology, 1962