Abstract
Magnetic flux leakage (MFL) is frequently used for pipeline inspection. Lift-off caused by welds and debris is an insidious problem that affects the acquired magnetic flux leakage data in pipeline MFL inspection, which is usually studied with 2D finite element simulation and experiments on a plate specimen. Firstly, the limitations of the above two methods are discussed. Then, a magnetic circuit model based on Kirchhoff's Law and the multi-branch parallel method is established to analyse the influence on the magnetising state inside the pipe wall when the magnetisers have eccentricity from the axis of the pipeline specimen. Furthermore, the effects of the lift-off (magnetiser offset and sensor lift-off) on MFL signals are studied by the 3D finite element method. The 3D finite element simulation results show that the magnetiser offset has no influence on the MFL signals. Finally, the validity of the magnetic circuit model and the simulation results are verified by experiment in a pipe specimen.