ExoBoot, a Soft Inflatable Robotic Boot to Assist Ankle During Walking: Design, Characterization and Preliminary Tests
Authors:
- Jinwon ChungJCJinwon Chung
- Roman HeimgartnerRHRoman Heimgartner
- Ciaran T. OneillCOCiaran T. Oneill
- 1 August 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 509-516
Abstract
In this paper, we present the design and characterization of the ExoBoot, a soft inflatable robotic boot for assisting ankle plantarflexion during walking. The ExoBoot integrates a soft textile-based actuator and an IMU sensor into a textile boot, making it low-profile and lightweight. The inflatable actuator generates assistive plantarflexion torque when pressurized by bending on top of the boot. We characterize the torque generated by the ExoBoot at various pressures and ankle angles, achieving a maximum torque of 39 Nm at 483 kPa (70 psi) and 60 degrees ankle angle. In order to evaluate the performance of the ExoBoot during walking, a pilot study with one healthy subject was conducted. Actuation is triggered by an open loop pressure controller, based on the ankle angular velocity measured by an IMU, using high flow rate solenoid valves. At the peak of active assistance, pressure in the actuator reaches 75% of the supply pressure, and maximum torque applied on the ankle is estimated to be 23 Nm. These results demonstrate potential for the ExoBoot to reduce the metabolic cost of walking.Keywords
This publication has 24 references indexed in Scilit:
- Autonomous exoskeleton reduces metabolic cost of human walking during load carriageJournal of NeuroEngineering and Rehabilitation, 2014
- Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitationBioinspiration & Biomimetics, 2014
- Feasibility Study of a Wearable Exoskeleton for Children: Is the Gait Altered by Adding Masses on Lower Limbs?PLOS ONE, 2013
- A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human WalkingPLOS ONE, 2013
- The mechanics and energetics of human walking and running: a joint level perspectiveJournal of The Royal Society Interface, 2011
- A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibitionJournal of NeuroEngineering and Rehabilitation, 2009
- A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATIONInternational Journal of Humanoid Robotics, 2007
- Walking speed, cadence and step length are selected to optimize the stability of head and pelvis accelerationsExperimental Brain Research, 2007
- The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of WalkingMedicine & Science in Sports & Exercise, 2007
- The Berkeley Lower Extremity ExoskeletonJournal of Dynamic Systems, Measurement, and Control, 2005