Effect of low level capacitive‐coupled pulsed electric field stimulation on mineral profile of weight‐bearing bones in ovariectomized rats
Authors:
- 6 October 2009
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 92B (1) , 189-195
Abstract
Mineral content, mineral composition, and crystalline pattern of bone in osteoporosis are different from those of normal individuals. Present management of bone mineral loss is rather unsatisfactory primarily because of socioeconomic factors and untoward effects of the treatment drugs. We report the efficacy of capacitive‐coupled pulsed electric field (CCPEF) to prevent bone loss in an ovariectomized rat model of osteoporosis. One month postsurgery either leg was stimulated with CCPEF, whereas the other leg did not receive any stimulation (sham exposed). The treatment was given in 60 sessions each of 2 h/d (5 days a week). The control group of rats was sham operated. At the end of the observation period, femur and tibia bones were removed. Their bone mineral content (BMC), calcium, phosphorus, and carbon contents were analyzed and bone mineral density (BMD) was calculated. The BMC data were supported by X‐ray diffraction (XRD) method. In sham‐exposed bones, a statistically significant decrease in BMC, BMD, calcium, and phosphorus contents were obtained as compared to the control. Although in CCPEF bones, there was an attenuation of decrement in the noted parameters except phosphorus. XRD pattern supported these observations. The results suggest that chronic, 60 sessions of 2 h/d, 5 d/wk CCPEF (14 MHz with 16 Hz modulation 16 Hz and 10 V peak to peak) is effective in attenuating the ovariectomy‐induced bone mineral loss in rats. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2010Keywords
This publication has 33 references indexed in Scilit:
- Cytokine Release from Osteoblasts in Response to Different Intensities of Pulsed Electromagnetic Field StimulationElectromagnetic Biology and Medicine, 2007
- Electrical field stimulation improves bone mineral density in ovariectomized ratsBrazilian Journal of Medical and Biological Research, 2006
- Expression Profiling of Rat Femur Revealed Suppression of Bone Formation Genes by Treatment with Alendronate and Estrogen but Not RaloxifeneMolecular Pharmacology, 2005
- Comparison of Bone Density Measurement Techniques: DXA and Archimedes' PrincipleJournal of Bone and Mineral Research, 1997
- The effect of aging and ovariectomy on the vertebral bone mass and biomechanical properties of mature ratsBone, 1993
- Bone mineral density in elderly men and women: Results from the framingham osteoporosis studyJournal of Bone and Mineral Research, 1992
- Electrical conduction in Bone in frequency range 0.4–1.3 ClizBiomaterials, Medical Devices, and Artificial Organs, 1986
- Physical characteristics of bone composite materialsJournal of Biological Physics, 1984
- Frequency Dependence of Electrical Properties of Human BoneJournal of Bioelectricity, 1984
- New concepts in the composition, crystallization and growth of the mineral component of calcified tissuesJournal of Crystal Growth, 1981