This study aims to determine an acquisitional and computational workflow that yields the highest quality spatio-spectral reconstructions in four-dimensional neutron tomography studies. The properties of neutrons enable unique image contrast modes, but accessing these modes requires defining the energy of the neutron beam, resulting in long acquisition times. We seek sparse angular tomography approaches to collect of order 100 tomograms at different neutron wavelengths using the minimum number of input projection images. In these computational image workflows, we identified and evaluated the main factors affecting the quality of the tomographic reconstruction such as the projection number, the reconstruction method, and the post-processing method and we report relationships between 3D reconstruction quality metrics and acquisition time. Based on these relationships, the performance of seeded simultaneous iterative reconstruction-based techniques (SIRT and SIRT with total variation regularization) yielded improved image quality and more accurate estimates of the reconstructed attenuation values compared to other methods, which included convolutional neural networks. The methods were then applied to a dose-reduced monochromatic dataset and characterized via signal-to-noise ratio (SNR) and single-voxel resolution.Keywords
This publication has 50 references indexed in Scilit:
- The ASTRA Toolbox: A platform for advanced algorithm development in electron tomographyUltramicroscopy, 2015
- General solution for quantitative dark-field contrast imaging with grating interferometersScientific Reports, 2014
- 3D Mapping of Crystallographic Phase Distribution using Energy‐Selective Neutron TomographyAdvanced Materials, 2014
- Analysis of focus measure operators for shape-from-focusPattern Recognition, 2013
- Noise evaluation of a digital neutron imaging deviceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2012
- Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs)Journal of Structural Biology, 2011
- A First-Order Primal-Dual Algorithm for Convex Problems with Applications to ImagingJournal of Mathematical Imaging and Vision, 2010
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- The blur effect: perception and estimation with a new no-reference perceptual blur metric2007
- Applications of Maxwell-Boltzmann distribution diagramsJournal of Chemical Education, 1992