Ventricular arrhythmias following transcatheter pulmonary valve replacement with the harmony TPV25 device
- 5 October 2022
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 100 (5) , 766-773
Abstract
Background: Transcatheter pulmonary valve replacement (TPVR) with the Harmony valve (Medtronic, Inc.) was recently approved to treat postoperative native outflow tract pulmonary regurgitation. While the 22 mm Harmony valve Early Feasibility Study demonstrated ventricular tachycardia (VT) in only 5% of patients, little is known about ventricular arrhythmias after TPVR with the larger 25 mm valve (TPV25).Methods: A single center review was performed of patients with TPV25 implant from 2020 to 2021. Demographic, cardiac, procedural, and postimplant cardiac telemetry data were collected and compared between patients who did and did not have peri‐implant ventricular arrhythmia.Results: Thirty patients underwent TPV25 at a median age of 30 years. On postimplant telemetry, VT events were documented in 12 patients (40%); 11 nonsustained VT (NSVT) (median 3 episodes per patient and 6 beats per episode, maximum 157 episodes) and 1 sustained VT (3%), with Torsades de Pointes secondary to a short coupled premature ventricular contraction (PVC). VT events were associated with annular valve positioning (p < 0.001) and increased postimplant PVC burden (p < 0.0001), but there was no association between VT and other demongraphic, historical, or procedural factors. The frequency of NSVT events fell from 3/h from 0 to 12 h postimplant to 0.5/hr from 12 to 24 h (p < 0.001).Conclusion: VT occurred commonly (40%) in the first 24 h after TPV25 implant, with self‐limited NSVT in 11 of 12 patients and 1 patient with cardiac arrest secondary to Torsades de Pointes. VT only occurred with annular valve positioning. Larger, longer‐term studies are needed to determine risk factors for and natural history of post‐TPVR VT.Keywords
This publication has 13 references indexed in Scilit:
- Risk of cardiac tachyarrhythmia in patients with repaired tetralogy of Fallot: a multicenter cardiac MRI based studyThe International Journal of Cardiovascular Imaging, 2018
- Safety and Feasibility of Melody Transcatheter Pulmonary Valve Replacement in the Native Right Ventricular Outflow TractJACC: Cardiovascular Interventions, 2018
- Ventricular arrhythmia burden after transcatheter versus surgical pulmonary valve replacementHeart, 2018
- Ventricular arrhythmias immediately following transcatheter pulmonary valve implantation: A cause for concern?Catheterization and Cardiovascular Interventions, 2017
- Percutaneous Pulmonary Valve Implantation Alters Electrophysiologic SubstrateJournal of the American Heart Association, 2016
- Percutaneous Pulmonary Valve Implantation‐Associated Ventricular Tachycardia in Congenital Heart DiseaseJournal of Interventional Cardiology, 2016
- Arrhythmic burdens in patients with tetralogy of Fallot: A national database studyHeart Rhythm, 2015
- Risk stratification in surgically repaired tetralogy of FallotExpert Review of Cardiovascular Therapy, 2009
- Risk factors for arrhythmia and sudden cardiac death late after repair of tetralogy of Fallot: a multicentre studyThe Lancet, 2000
- Electrophysiologic characteristics of sustained ventricular tachycardia occurring after repair of tetralogy of fallotThe American Journal of Cardiology, 1980