Development of a New Calibration Procedure and Its Experimental Validation Applied to a Human Motion Capture System
- 15 October 2014
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (12) , 124502
Abstract
Motion capture systems are often used for checking and analyzing human motion in biomechanical applications. It is important, in this context, that the systems provide the best possible accuracy. Among existing capture systems, optical systems are those with the highest accuracy. In this paper, the development of a new calibration procedure for optical human motion capture systems is presented. The performance and effectiveness of that new calibration procedure are also checked by experimental validation. The new calibration procedure consists of two stages. In the first stage, initial estimators of intrinsic and extrinsic parameters are sought. The camera calibration method used in this stage is the one proposed by Tsai. These parameters are determined from the camera characteristics, the spatial position of the camera, and the center of the capture volume. In the second stage, a simultaneous nonlinear optimization of all parameters is performed to identify the optimal values, which minimize the objective function. The objective function, in this case, minimizes two errors. The first error is the distance error between two markers placed in a wand. The second error is the error of position and orientation of the retroreflective markers of a static calibration object. The real co-ordinates of the two objects are calibrated in a co-ordinate measuring machine (CMM). The OrthoBio system is used to validate the new calibration procedure. Results are 90% lower than those from the previous calibration software and broadly comparable with results from a similarly configured Vicon system.Keywords
This publication has 18 references indexed in Scilit:
- Robust Identification of Three-Dimensional Thumb and Index Finger Kinematics With a Minimal Set of MarkersJournal of Biomechanical Engineering, 2013
- Velocity-dependent changes of rotational axes during the control of unconstrained 3D arm motions depend on initial instruction on limb positionHuman Movement Science, 2013
- Movement of the Distal Carpal Row During Narrowing and Widening of the Carpal Arch WidthJournal of Biomechanical Engineering, 2012
- Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable SystemJournal of Biomechanical Engineering, 2012
- A Methodology for Quantifying Seated Lumbar CurvaturesJournal of Biomechanical Engineering, 2011
- Gait Modification via Verbal Instruction and an Active Feedback System to Reduce Peak Knee Adduction MomentJournal of Biomechanical Engineering, 2010
- A Mechanical Model of the Human Ankle in the Transverse Plane During Straight Walking: Implications for Prosthetic DesignJournal of Biomechanical Engineering, 2008
- Development of a spine kinematic model for the clinical estimation of abnormal curvature2007
- Three-dimensional kinematic motion analysis of a daily activity drinking from a glass: a pilot studyJournal of NeuroEngineering and Rehabilitation, 2006
- Relationship between the movements of the lumbar spine and hipHuman Movement Science, 2002