Catheter ablation for atrial fibrillation can be safely performed without invasive hemodynamic monitoring: A multi-center study
- 19 February 2022
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 64 (3) , 743-749
Abstract
Background Arterial invasive monitoring is the most common method in the USA for hemodynamic monitoring during atrial fibrillation (AF) ablation. Although studies have shown favorable comparison between non-invasive and invasive hemodynamic monitoring (IHM) in non-cardiac procedures under general anesthesia, limited data is available for complex cardiac procedures such as AF ablation in the USA. With progressive improvement in AF ablation procedural safety, particularly with routine use of intracardiac echocardiography (ICE) to monitor for pericardial effusion, it is unclear if invasive hemodynamic monitoring provides any advantage over non-invasive methods. Therefore, the purpose of this study is to determine whether noninvasive hemodynamic monitoring is non-inferior to invasive hemodynamic monitoring during AF ablation under general anesthesia in patients without major cardiac structural abnormality. Methods A multi-center retrospective data of AF ablation from July 2019 to December 2020 was extracted. A total of three hundred and sixty-two patients (362) were included, which were divided into group A (non-invasive hemodynamic monitoring) and group B (invasive hemodynamic monitoring). The primary outcome was to compare procedural safety between the two groups. Results Out of 362 patients, 184 (51%) received non-invasive and 178 (49%) received invasive hemodynamic monitoring with similar baseline characteristics. There was no significant difference between the two groups in complication rates (groin hematoma, pericardial effusion, cardiac tamponade). Mean procedure time was longer in group B with 3.35% arterial site discomfort. Urgent arterial access was required in only 1 patient in group A. Conclusion This retrospective multicenter study strongly suggests that catheter ablation for atrial fibrillation under general anesthesia can be safely performed with noninvasive hemodynamic monitoring without requiring arterial access, with potential benefit in procedural duration and cost.Keywords
This publication has 31 references indexed in Scilit:
- Improving Safety in Catheter Ablation for Atrial Fibrillation: A Prospective Study of the Use of Ultrasound to Guide Vascular AccessJournal of Cardiovascular Electrophysiology, 2014
- Should surgical ablation for atrial fibrillation be performed in patients with a significantly enlarged left atrium?The Journal of Thoracic and Cardiovascular Surgery, 2014
- Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure MonitoringHypertension, 2013
- Nexfin Noninvasive Continuous Hemodynamic Monitoring: Validation against Continuous Pulse Contour and Intermittent Transpulmonary Thermodilution Derived Cardiac Output in Critically Ill PatientsThe Scientific World Journal, 2013
- Systematic Review and Cost–Benefit Analysis of Radial Artery Access for Coronary Angiography and InterventionCirculation: Cardiovascular Quality and Outcomes, 2012
- Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®Anesthesiology, 2012
- A comparison of the Nexfin ® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgeryAnaesthesia, 2012
- Intracardiac Echocardiography Improves Procedural Efficiency During Cryoballoon Ablation for Atrial Fibrillation: A Pilot StudyJournal of Cardiovascular Electrophysiology, 2010
- Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiologyEP Europace, 2010
- Perioperative haemodynamic therapyCurrent Opinion in Critical Care, 2010