Discordance between postprandial plasma glucose measurement and continuous glucose monitoring
- 1 July 2022
- journal article
- research article
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 116 (4) , 1059-1069
Abstract
There has been growing interest in studying postprandial glucose responses using continuous glucose monitoring (CGM) in nondiabetic individuals. Accurate measurement of glucose responses to meals can facilitate applications such as precision nutrition and early detection of diabetes. We aimed to quantify the discordance between simultaneous postprandial glucose measurements made using plasma and CGM. We studied 10 nondiabetic older adults who randomly consumed 9 predefined meals of varying macronutrient compositions. Glucose was measured for 8 h after the meal by the CGM, blood samples for plasma collection were taken regularly, and plasma glucose was quantified using gold-standard laboratory measurement and a fingerstick blood glucose meter. The primary outcome measured was the mean absolute relative difference (MARD) of CGM and fingerstick measurements relative to the gold standard. Secondary outcomes were Bland–Altman statistics, Clarke Error Grid, and time in range metrics. Additional subgroup analyses were performed by stratifying the postprandial glucose measurements based on the macronutrient composition of the meals. When compared against the gold-standard postprandial glucose measurements, the fingerstick meter was more accurate (MARD: 8.0%; 95% CI: 7.6%, 8.6%) than the CGM (MARD: 13.7%; 95% CI: 13.1%, 14.3%; P < 0.0001). After the meals, Bland–Altman analysis demonstrated that the CGM underestimated the 8-h gold-standard glucose rise by 12.8 mg/dL on average (P < 0.0001), whereas the fingerstick meter did so by 5.5 mg/dL on average (P < 0.0001). The CGM underestimated the time spent in the 70–180 mg/dL range (P = 0.002) and overestimated the time spent P < 0.0001) compared with the other 2 methods. We discovered discordance between gold standard, fingerstick, and CGM in measuring plasma glucose concentrations after a meal. Consequently, emerging applications of CGM in healthy individuals, such as precision nutrition and diabetes onset prediction, may need to account for these discordances. This trial was registered at clinicaltrials.gov as NCT04928872.Keywords
Funding Information
- National Science Foundation (1648451)
This publication has 46 references indexed in Scilit:
- Rate-of-Change Dependence of the Performance of Two CGM Systems During Induced Glucose SwingsJournal of Diabetes Science and Technology, 2015
- Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose MonitoringDiabetes Technology & Therapeutics, 2015
- Major food sources of calories, added sugars, and saturated fat and their contribution to essential nutrient intakes in the U.S. diet: data from the national health and nutrition examination survey (2003–2006)Nutrition Journal, 2013
- Informing food choices and health outcomes by use of the dietary glycemic indexNutrition Reviews, 2011
- A Tale of Two Compartments: Interstitial Versus Blood Glucose MonitoringDiabetes Technology & Therapeutics, 2009
- Fast food: unfriendly and unhealthyInternational Journal of Obesity, 2007
- Effect of Added Fat on the Plasma Glucose and Insulin Response to Ingested Potato Given in Various Combinations as Two Meals in Normal IndividualsDiabetes Care, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Plasma glucose and insulin profiles in normal subjects ingesting diets of varying carbohydrate, fat, and protein content.Journal of the American College of Nutrition, 1985
- Use of a heated superficial hand vein as an alternative site for the measurement of amino acid concentrations and for the study of glucose and alanine kinetics in manMetabolism, 1981