Electrical stimulation for the suppression of pathological tremor
- 14 July 2011
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 49 (10) , 1187-1193
Abstract
Pathological tremor is manifested as an involuntary oscillation of one or more body parts. Tremor greatly decreases the quality of life and often prevents the patient from performing daily activities. We hypothesized that sensors-driven multichannel electrical stimulation could stabilize affected joints by activating the antagonistic muscles during involuntary activation of agonist muscles and vice versa (out-of-phase stimulation). Here, we present the new system (hardware and software) and the testing of its operation. The hardware consists of a multichannel stimulator and inertial sensors for feedback. The software implements adaptive sensors-driven control for the out-of-phase stimulation. The system was initially applied to healthy persons at the wrist and elbow joints to test the efficiency of the hardware and software solutions. Predefined rhythmic stimulation resulted in tremulous movement, which subjects could not prevent; yet, they were still able to functionally use their hand. The system was then applied to seven patients with Parkinson’s disease and essential tremor for minimization of the wrist joint tremor. In six patients, the adaptive out-of-phase stimulation resulted in a significant decrease in the amplitude of tremor (67 ± 13%). In one patient, the stimulation did not result in the expected reduction of tremor.Keywords
This publication has 19 references indexed in Scilit:
- Distributed low‐frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulationMuscle & Nerve, 2010
- Adaptive band-pass filter (ABPF) for tremor extraction from inertial sensor dataComputer Methods and Programs in Biomedicine, 2010
- Muscle twitch responses for shaping the multi-pad electrode for functional electrical stimulationJournal of Automatic Control, 2010
- Automatic determination of the optimal shape of a surface electrode: Selective stimulationJournal of Neuroscience Methods, 2009
- Consensus Statement of the Movement Disorder Society on TremorMovement Disorders, 2008
- Tremor: From Pathogenesis to TreatmentSynthesis Lectures on Biomedical Engineering, 2008
- Reciprocal EMG Controlled FES for Pathological Tremor Suppression of Forearm2007
- Mechanical suppression of essential tremorThe Cerebellum, 2007
- Multi‐Field Surface Electrode for Selective Electrical StimulationArtificial Organs, 2005
- Attenuation of pathological tremors by functional electrical stimulation II: Clinical evaluationAnnals of Biomedical Engineering, 1992