Semiautomatic segmentation of aortic valve from sequenced ultrasound image using a novel shape-constraint GCV model
Authors:
- 3 June 2014
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 41 (7) , 072901
Abstract
Effective and accurate segmentation of the aortic valve (AV) from sequenced ultrasound (US) images remains a technical challenge because of intrinsic factors of ultrasound images that impact the quality and the continuous changes of shape and position of segmented objects. In this paper, a novel shape-constraint gradient Chan-Vese (GCV) model is proposed for segmenting the AV from time serial echocardiography. The GCV model is derived by incorporating the energy of the gradient vector flow into a CV model framework, where the gradient vector energy term is introduced by calculating the deviation angle between the inward normal force of the evolution contour and the gradient vector force. The flow force enlarges the capture range and enhances the blurred boundaries of objects. This is achieved by adding a circle-like contour (constructed using the AV structure region as a constraint shape) as an energy item to the GCV model through the shape comparison function. This shape-constrained energy can enhance the image constraint force by effectively connecting separate gaps of the object edge as well as driving the evolution contour to quickly approach the ideal object. Because of the slight movement of the AV in adjacent frames, the initial constraint shape is defined by users, with the other constraint shapes being derived from the segmentation results of adjacent sequence frames after morphological filtering. The AV is segmented from the US images by minimizing the proposed energy function. To evaluate the performance of the proposed method, five assessment parameters were used to compare it with manual delineations performed by radiologists (gold standards). Three hundred and fifteen images acquired from nine groups were analyzed in the experiment. The area-metric overlap error rate was 6.89% ± 2.88%, the relative area difference rate 3.94% ± 2.63%, the average symmetric contour distance 1.08 ± 0.43 mm, the root mean square symmetric contour distance 1.37 ± 0.52 mm, and the maximum symmetric contour distance was 3.57 ± 1.72 mm. Compared with the CV model, as a result of the combination of the gradient vector and neighborhood shape information, this semiautomatic segmentation method significantly improves the accuracy and robustness of AV segmentation, making it feasible for improved segmentation of aortic valves from US images that have fuzzy boundaries.Keywords
Funding Information
- NSFC (61190120-61190124)
- NSFC (61271318)
- National Natural Science Foundation of China (61190120-61190124, 61271318)
- National Natural Science Foundation of China (61190120-61190124, 61271318)
This publication has 24 references indexed in Scilit:
- A pilot study on magnetic navigation for transcatheter aortic valve implantation using dynamic aortic model and US image guidanceInternational Journal of Computer Assisted Radiology and Surgery, 2013
- A novel segmentation method for breast ultrasound images based on neutrosophic l‐means clusteringMedical Physics, 2012
- The Year in Valvular Heart DiseaseJACC, 2012
- A Novel Approach to Medical Image SegmentationJournal of Computer Science, 2011
- Ultrasound speckle and equivalent scatterersUltrasonics, 2005
- Active contours without edgesIEEE Transactions on Image Processing, 2001
- Snakes, shapes, and gradient vector flowIEEE Transactions on Image Processing, 1998
- A two-dimensional extension of minimum cross entropy thresholding for the segmentation of ultrasound imagesUltrasound in Medicine & Biology, 1996
- Fronts propagating with curvature-dependent speed: Algorithms based on Hamilton-Jacobi formulationsJournal of Computational Physics, 1988
- Segmentation of echocardiographic images using mathematical morphologyIEEE Transactions on Biomedical Engineering, 1988