Determining aquifer transmissivity by means of well response tests: The underdamped case
Author:
- Garth van der KampGKGarth van der Kamp
- 1 February 1976
- journal article
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 12 (1) , 71-77
Abstract
Well response tests, often referred to as slug tests, provide a relatively simple and inexpensive method for estimating aquifer transmissivity. An approximate theory is developed for the problem of underdamped well response where the inertia of the water in the well column results in force‐free oscillation of the water level in the well. This type of response is often encountered in conjunction with highly permeable aquifers. The theory is applicable for nearly all such cases except those where the oscillation is very quickly damped out. Theoretical predictions compare well with empirical results and indicate that the theory may be used to obtain estimates of aquifer transmissivity. This theory for the underdamped case together with existing theory for overdamped response makes it possible to obtain an estimate of transmissivity from well response tests for almost any aquifer.Keywords
This publication has 5 references indexed in Scilit:
- On the analysis of ‘slug test’ dataWater Resources Research, 1973
- Response of a finite‐diameter well to an instantaneous charge of waterWater Resources Research, 1967
- Inertial and storage effects in well‐aquifer systems: An analog investigationWater Resources Research, 1966
- The response of well-aquifer systems to seismic wavesJournal of Geophysical Research, 1965
- Microtime Measurements of Ground‐Water Level FluctuationsGroundwater, 1963