Comparison of High-Frequency Circular Array Imaging Algorithms for Intravascular Ultrasound Imaging Simulations
Open Access
- 25 November 2025
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4623
Abstract
A circular array transducer with high frequency and small aperture size is highly desired for intravascular ultrasound (IVUS) imaging application. With the breakthrough of array transducer techniques, high-frequency circular array transducers with the advantages of high frame rate and high resolution have been developed and manufactured. Focusing on the development of a matched high-frequency imaging algorithms, this study introduces apodization functions into 55 MHz circular-array IVUS imaging, proposes a circular-array-specific apodization model, and breaks the lateral-resolution limit inherent to conventional delay-and-sum (DAS) beamforming. In the study, three typical algorithms—synthetic aperture (SA), apodized synthetic aperture (ASA), and sparse synthetic aperture (SSA)—are investigated in order to well achieve an effective imaging result for our newly derived circular array transducer with 55 MHz. In the scatterer’s simulation, at a depth of 1.5 mm, the ASA algorithm improves the lateral resolution from 260 μm for conventional SA to 175 μm (a 33% enhancement), while tripling the frame rate. Meanwhile, SSA maintains a resolution of 300 μm and reduces the data volume by 50%, laying the groundwork for real-time 3D imaging. Further phantom imaging testing shows that the SA algorithm has the best imaging effect on regional defects. The ASA algorithm has the best imaging effect on point defects while improving the imaging frame rate. This study provides insights and a foundation for optimizing circular-array intravascular ultrasound imaging, the proposed ASA model can be directly ported to existing 40–60 MHz circular-array IVUS systems, offering a new route for accurate early-plaque identification.Keywords
Funding Information
- Guangdong Innovation and Entrepreneurship Team (2021ZT09X070)
- Guangdong Zhujiang Leadership Project (2021CX02X011)
This publication has 35 references indexed in Scilit:
- High frequency ultrasound 2D array design and fabrication with 3D printed interposers at 200 μm pitchUltrasonics, 2025
- An omega‐ k algorithm for multireceiver synthetic aperture sonarElectronics Letters, 2023
- Optimally-weighted non-linear beamformer for conventional focused beam ultrasound imaging systemsScientific Reports, 2021
- Effectiveness of synthetic aperture focusing and coherence factor weighting for intravascular ultrasound imagingUltrasonics, 2021
- Capacitive micromachined ultrasound transducers for intravascular ultrasound imagingMicrosystems & Nanoengineering, 2020
- Monolithic ultrasound fingerprint sensorMicrosystems & Nanoengineering, 2017
- Adaptive windowing in contrast-enhanced intravascular ultrasound imagingUltrasonics, 2016
- Angled-focused 45MHz PMN-PT single element transducer for intravascular ultrasound imagingSensors and Actuators A: Physical, 2015
- Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom modelUltrasound in Medicine & Biology, 2007
- In vitro and in vivo comparison of three different intravascular ultrasound catheter designsCatheterization and Cardiovascular Interventions, 2001