Measurement of magnetization transfer ratio (MTR) from cervical spinal cord: Multicenter reproducibility and variability
- 22 October 2018
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 49 (6) , 1777-1785
Abstract
Background: Assessing the multicenter variability of magnetization transfer ratio (MTR) measurements in the spinal cord of healthy controls is the first step toward investigating its clinical use as a biomarker.Purpose: To analyze the between‐session, between‐participant, and between‐scanner variability of MTR measurements in automatically extracted regions of interest in the cervical cord of healthy controls.Study Type: Control study.Population: Forty‐four participants, distributed across five MRI scanners (all from the same manufacturer). Ten participants were scanned twice in the same scanner, and 10 others were scanned twice in two different scanners.Field Strength/Sequence: 3D‐gradient echo images, centered on C5, without and with magnetization transfer prepulse at 3T.Assessment: We calculated the mean MTR for different vertebral levels in the whole cord (WC), as well as in the white matter and gray matter, and determined the between‐session, between‐participant, and between‐scanner variabilities.Statistical Tests: Coefficients of variation and intraclass correlations (ICCs) for the different variabilities and their associated confidence intervals.Results: The MTR measurements for Levels C4‐C6 (near the slab center) exhibited a mean value in WC of 34.6 pu and a pooled standard deviation of 0.9 pu. The between‐session coefficient of variation was estimated as 2.3% (ICC = 0.63), the between‐participant coefficient as 1.6% (ICC = 0.32), and the between‐scanner coefficient as 0.7% (ICC = 0.05). The resulting aggregate coefficient of variation was 2.9%, which was sufficiently low to detect an MTR reduction of 1 pu between groups of about 45 participants (Type‐I error rate: 0.05; Type‐II error rate: 0.10).Data Conclusion: The good between‐scanner reproducibility and low overall variability in cervical spinal cord MTR measurements in a control population might pave the way for multicenter analyses in various neurological diseases with moderate cohort sizes.Level of Evidence: 2Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;49:1777–1785.Keywords
Funding Information
- Hospital Program of Clinical Research (PHRC)
This publication has 28 references indexed in Scilit:
- Translating state-of-the-art spinal cord MRI techniques to clinical use: A systematic review of clinical studies utilizing DTI, MT, MWF, MRS, and fMRINeuroImage: Clinical, 2016
- Relationships between quantitative spinal cord MRI and retinal layers in multiple sclerosisNeurology, 2015
- Cervical cord lesion load is associated with disability independently from atrophy in MSNeurology, 2015
- Investigation of magnetization transfer ratio-derived pial and subpial abnormalities in the multiple sclerosis spinal cordBrain, 2014
- The current state-of-the-art of spinal cord imaging: MethodsNeuroImage, 2014
- Absence of diffuse cervical cord tissue damage in early, non-disabling relapsing-remitting MS: a preliminary studyMultiple Sclerosis Journal, 2008
- Associations Between Cervical Cord Gray Matter Damage and Disability in Patients With Multiple SclerosisArchives of Neurology, 2007
- Correlations between Structural CNS Damage and Functional MRI Changes in Primary Progressive MSNeuroImage, 2002
- In vivo assessment of the brain and cervical cord pathology of patients with primary progressive multiple sclerosisBrain, 2001
- Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosisNeuroradiology, 1997