Cerebral circulation during mild +Gz hypergravity by short-arm human centrifuge
Open Access
- 1 January 2012
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 112 (2) , 266-271
Abstract
We examined changes in cerebral circulation in 15 healthy men during exposure to mild +Gz hypergravity (1.5 Gz, head-to-foot) using a short-arm centrifuge. Continuous arterial pressure waveform (tonometry), cerebral blood flow (CBF) velocity in the middle cerebral artery (transcranial Doppler ultrasonography), and partial pressure of end-tidal carbon dioxide (ETco2) were measured in the sitting position (1 Gz) and during 21 min of exposure to mild hypergravity (1.5 Gz). Dynamic cerebral autoregulation was assessed by spectral and transfer function analysis between beat-to-beat mean arterial pressure (MAP) and mean CBF velocity (MCBFV). Steady-state MAP did not change, but MCBFV was significantly reduced with 1.5 Gz (−7%). ETco2 was also reduced (−12%). Variability of MAP increased significantly with 1.5 Gz in low (53%)- and high-frequency ranges (88%), but variability of MCBFV did not change in these frequency ranges, resulting in significant decreases in transfer function gain between MAP and MCBFV (gain in low-frequency range, −17%; gain in high-frequency range, −13%). In contrast, all of these indexes in the very low-frequency range were unchanged. Transfer from arterial pressure oscillations to CBF fluctuations was thus suppressed in low- and high-frequency ranges. These results suggest that steady-state global CBF was reduced, but dynamic cerebral autoregulation in low- and high-frequency ranges was improved with stabilization of CBF fluctuations despite increases in arterial pressure oscillations during mild +Gz hypergravity. We speculate that this improvement in dynamic cerebral autoregulation within these frequency ranges may have been due to compensatory effects against the reduction in steady-state global CBF.Keywords
This publication has 36 references indexed in Scilit:
- Impairment of Cerebral Blood Flow Regulation in Astronauts With Orthostatic Intolerance After FlightStroke, 2011
- Transient influence of end-tidal carbon dioxide tension on the postural restraint in cerebral perfusionJournal of Applied Physiology, 2009
- Artificial gravity as a countermeasure to microgravity: a pilot study examining the effects on knee extensor and plantar flexor muscle groupsJournal of Applied Physiology, 2009
- Tidal volume, cardiac output and functional residual capacity determine end‐tidal CO2 transient during standing up in humansThe Journal of Physiology, 2004
- Dynamic modulation of cerebrovascular resistance as an index of autoregulation under tilt and controlled Pet CO2 American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2002
- Effects of repeated long duration +2Gz load on man's cardiovascular functionActa Astronautica, 1998
- Cerebral Arterial Diameters during Changes in Blood Pressure and Carbon Dioxide during CraniotomyNeurosurgery, 1993
- Cerebral autoregulation dynamics in humans.Stroke, 1989
- Transcranial Doppler measurement of middle cerebral artery blood flow velocity: a validation study.Stroke, 1986
- Effect of Contrast Material, Hypercapnia, Hyperventilation, Hypertonic Glucose and Papaverine on the Diameter of the Cerebral ArteriesInvestigative Radiology, 1967