Internal Spinal Fixator Stiffness Has Only a Minor Influence on Stresses in the Adjacent Discs
Authors:
- Antonius RohlmannARAntonius Rohlmann
- Jorge CalisseJCJorge Calisse
- Georg BergmannGBGeorg Bergmann
- Ulrich WeberUWUlrich Weber
- 1 June 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 24 (12) , 1192-1196
Abstract
Stresses in vertebral endplates and discs were calculated using the three-dimensional nonlinear finite-element model of a lumbar spine with an internal spinal fixation device. To determine the influence of fixator stiffness on stresses in the adjacent discs. There are few computer models of the lumbar spine with a fixator. Most of these models neglect the muscle forces. Fixator stiffness is assumed to influence greatly the stresses in the adjacent discs. Two three-dimensional nonlinear finite-element models were used to determine stresses in the lumbar spine for standing and 60° flexion of the upper body. One model had an internal spinal fixator, the other did not. In a parameter study, the diameters of the longitudinal rod of the fixator were assumed to be 3, 5, 7, and 10 mm. In the computer model, the forces of the trunk muscles were simulated. The diameter of the longitudinal rod strongly affected the fixator loads but hardly influenced the stresses in the vertebral endplates. The stresses in the bridged discs were strongly reduced. However, the internal fixator had only a minor influence on the stresses in the anulus fibrosus and the pressure in the nucleus pulposus of the adjacent discs. The stiffness of an internal spinal fixation device has only a minor influence on stresses in the adjacent discs.Keywords
This publication has 16 references indexed in Scilit:
- A New Technique for Measuring Lumbar Segmental Motion In VivoSpine, 1997
- Telemeterized Load Measurement Using Instrumented spinal Internal Fixators in a Patient With Degenerative InstabilitySpine, 1995
- Role of Ligaments and Facets in Lumbar Spinal StabilitySpine, 1995
- Interlaminar Shear Stresses and Laminae Separation in a DiscSpine, 1995
- A Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal FusionSpine, 1994
- The Effects of Pedicle Screw FitSpine, 1994
- Three-dimensional geometrical and mechanical modelling of the lumbar spineJournal of Biomechanics, 1992
- An Analytical Investigation of the Mechanics of Spinal InstrumentationSpine, 1988
- A finite element study of a lumbar motion segment subjected to pure sagittal plane momentsJournal of Biomechanics, 1986
- Effects of Disc Injury on Mechanical Behavior of the Human SpineSpine, 1984