Causes of intrastromal corneal ring segment explantation: Clinicopathologic correlation analysis
Authors:
- Consuelo FerrerCFConsuelo Ferrer
- Jorge L. AlióJAJorge L. Alió
- Antonio Uceda MontañésAMAntonio Uceda Montañés
- Jose J. Pérez-SantonjaJPJose J. Pérez-Santonja
- Miguel A. Diaz del RioMRMiguel A. Diaz del Rio
- Juan Alvarez de ToledoJTJuan Alvarez de Toledo
- Miguel A. TeusMTMiguel A. Teus
- Jaime JavaloyJJJaime Javaloy
- 1 June 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (6) , 970-977
Abstract
To determine the main causes of intrastromal corneal ring segment (ICRS) explantation and the relationship with the microscopic findings on the ICRS surface. Vissum Corporation-Instituto Oftalmológico de Alicante, Alicante, Spain. This study evaluated ICRS that were explanted in centers in Spain from 2000 to 2008. Clinical data (reasons for explantation, date of implantation/explantation, tunnel creation technique, ICRS type) and scanning electron microscopy findings on the ICRS surface (adherent tissue-like material, cell deposits, protein) were documented. Intrastromal corneal ring segments were explanted from 58 eyes (47 patients). The main cause was extrusion (48.2% of explanted segments), followed by refractive failure (ie, poor refractive outcome) (37.9%), keratitis (6.8%; 3.7% culture positive), and corneal melting and perforation (6.8%). Scanning electron microscopy showed cells and cell debris on the ICRS explanted by extrusion, a clean surface on the ICRS explanted for refractive failure, and bacteria (cocci) in the case of proven infectious keratitis. The main cause of explantation was extrusion of the ICRS followed by refractive failure. There was a clear correlation between the cause of explantation and the microscopic findings on the ICRS. Extrusion was accompanied by inflammatory cells and cell debris on the ICRS surface. No inflammatory reaction was observed on the ICRS explanted for refractive failure.Keywords
This publication has 30 references indexed in Scilit:
- Intacs implantation using a femtosecond laser for management of keratoconus: Comparison of 306 cases in different stagesJournal of Cataract & Refractive Surgery, 2008
- Intracorneal ring segment implantation for the management of keratoconus: Safety and efficacyJournal of Cataract & Refractive Surgery, 2007
- Intracorneal rings for keratoconus and keratectasiaJournal of Cataract & Refractive Surgery, 2007
- Intracorneal ring segments for keratoconus correction: Long-term follow-upJournal of Cataract & Refractive Surgery, 2006
- European clinical evaluation: Use of Intacs for the treatment of keratoconusJournal of Cataract & Refractive Surgery, 2006
- Modified Intracorneal Ring Segment Implantations (INTACS) for the Management of Moderate to Advanced KeratoconusCornea, 2006
- Long-term histopathologic findings in human corneal wounds after refractive surgical proceduresAmerican Journal of Ophthalmology, 2005
- Morphologic Characteristics of Lamellar Channel Deposits in the Human EyeCornea, 2004
- Changes in keratoconic corneas after intracorneal ring segment explantation and reimplantation*1Ophthalmology, 2004