Calcitonin measurement on fine needle washouts: Preanalytical Issues and Normal Reference Values
- 5 December 2011
- journal article
- research article
- Published by Wiley in Diagnostic Cytopathology
- Vol. 41 (3) , 226-229
Abstract
Calcitonin (CT) measurement on fine‐needle aspiration cytology (FNAC) washouts (FNAC‐CT) is a promising tool in the diagnosis of medullary thyroid carcinoma (MTC). Guidelines for the method with codified cut‐off are needed to use this technique in clinical routine. This study was undertaken to assess the best pre‐analytical procedure and to define a reliable reference value for FNAC‐CT. Fifty‐four patients underwent thyroid surgery, so MTC was excluded by surgical pathology examination and CT immunostains. Before surgery, FNAC‐CT was measured on 78 thyroid nodules from such 54 patients. Needles were rinsed by normal saline and specific CT‐free dilution buffer, and CT was measured by a fully automated immunochemiluminometric assay. FNAC‐CT levels were not significantly different in normal saline or specific buffer. The calculated 97.5th upper FNAC‐CT value was 8.5 pg/mL (saline) and 7.43 pg/mL (buffer), respectively. Seeing its relatively large sample size, rigorous selection criteria and inclusion of CT immunostaining of thyroid nodules, the present study provides a reliable guideline and a clinically relevant reference value for FNAC‐CT measurement in thyroid nodules. Diagn. Cytopathol. 2013.Keywords
This publication has 11 references indexed in Scilit:
- American Association Of Clinical Endocrinologists, Associazione Medici Endocrinologi, And European Thyroid Association Medical Guidelines For Clinical Practice For The Diagnosis And Management Of Thyroid NodulesJournal of Endocrinological Investigation, 2010
- Calcitonin Estimation in Neck Lymph Node Fine-Needle Aspirate Fluid Prevents Misinterpretation of Cytology in Patients with Metastatic Medullary Thyroid CancerThyroid®, 2009
- Potency and Tolerance of Calcitonin Stimulation with High-Dose CalciumVersusPentagastrin in Normal AdultsThe Journal of Clinical Endocrinology & Metabolism, 2009
- Calcitonin assay in wash-out fluid after fine-needle aspiration biopsy in patients with a thyroid nodule and border-line value of the hormoneJournal of Endocrinological Investigation, 2009
- Routine serum calcitonin measurement in the evaluation of thyroid nodulesBest Practice & Research Clinical Endocrinology & Metabolism, 2008
- Thyroglobulin measurement on fine‐needle washout fluids: Influence of sample collection methodsDiagnostic Cytopathology, 2008
- Diagnosis of Medullary Thyroid Carcinoma by Calcitonin Measurement in Fine-Needle Aspiration Biopsy SpecimensThyroid®, 2007
- Calcitonin Measurement in Wash-Out Fluid from Fine Needle Aspiration of Neck Masses in Patients with Primary and Metastatic Medullary Thyroid CarcinomaThe Journal of Clinical Endocrinology & Metabolism, 2007
- Calcitonin Measurement to Detect Medullary Thyroid Carcinoma in Nodular Goiter: German Evidence-Based Consensus RecommendationExperimental and Clinical Endocrinology & Diabetes, 2004
- Pentagastrin stimulation test and early diagnosis of medullary thyroid carcinoma using an immunoradiometric assay of calcitonin: comparison with genetic screening in hereditary medullary thyroid carcinomaThe Journal of Clinical Endocrinology & Metabolism, 1994