Energy-Loss and Stopping-Power Measurements between 2 and 10 MeV/amu forC12,N14, andO16in Silicon

Authors:

Abstract
The energy deposited in a 94.6-μm-thick totally depleted silicon detector by beams of C12, N14, and O16 was measured at incident energies up to 10 MeV/amu. Theoretical stopping powers for these ions are derived from best theoretical values for protons and a universal distribution of ion charges as a function of energy. The effect of a recently derived z3 correction is included. This correction is found to improve the fit to the experimental values.

This publication has 13 references indexed in Scilit: