1 mm ID poly(styrene‐co‐divinylbenzene) monolithic columns for high‐peak capacity one‐ and two‐dimensional liquid chromatographic separations of intact proteins
- 7 August 2009
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 32 (15-16) , 2504-2509
Abstract
The LC performance of a 1×50 mm polymer monolithic column format was demonstrated with high‐peak capacity one‐ (1D) and offline two dimensional (2D) LC separations of intact proteins. After optimizing the RP 1D‐LC conditions, including column temperature, flow rate and gradient time, a peak capacity of 475 was achieved within a 2‐h analysis. The suitability of the monolithic column was also demonstrated for fast 1 min protein separations yielding 1 s peak widths determined at half peak height. In addition, an offline 2D‐LC method was developed using the micro‐fraction collection capabilities of the autosampler allowing automatic fractionation of intact proteins after the weak‐ion‐exchange (WAX) separation, and re‐injection of the fractions onto the second‐dimension RP monolithic column. The best peak capacity‐to‐analysis time ratio was obtained when applying 10 min second‐dimension RP gradients. At optimized conditions, the WAX/×/RPLC separation of intact Escherichia coli proteins was performed within 6 h yielding a maximum theoretical peak capacity of 4880.Keywords
This publication has 26 references indexed in Scilit:
- Monolithic porous polymer stationary phases in polyimide chips for the fast high-performance liquid chromatography separation of proteins and peptidesJournal of Chromatography A, 2008
- Developments in ion chromatography using monolithic columnsJournal of Separation Science, 2007
- Use of monolithic supports in proteomics technologyJournal of Chromatography A, 2007
- Assessing the Macroporous Structure of Monolithic Columns by Transmission Electron MicroscopyAnalytical Chemistry, 2006
- A study of surface modification and anchoring techniques used in the preparation of monolithic microcolumns in fused silica capillariesJournal of Separation Science, 2006
- Preparation and HPLC applications of rigid macroporous organic polymer monolithsJournal of Separation Science, 2004
- Enantiomeric separations of primary amino compounds by capillary electrochromatography with monolithic chiral stationary phases of chiral crown ether-bonded negatively charged polyacrylamide gelsJournal of Chromatography A, 2001
- Rigid porous polyacrylamide-based monolithic columns containing butyl methacrylate as a separation medium for the rapid hydrophobic interaction chromatography of proteinsJournal of Chromatography A, 1997
- Highly permeable open-pore polyurethane columns for liquid chromatographyJournal of Chromatography A, 1974
- Gel permeation chromatography on porous poly(ethylene glycol methacrylate)Collection of Czechoslovak Chemical Communications, 1967