Comparative analysis of three platforms for serum NfL quantification in healthy controls and MS patients
Open Access
- 26 November 2025
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 64 (4) , 880-888
Abstract
Objectives: Neurofilament light chain (NfL) is a biomarker of neuroaxonal damage in various neurological conditions, including multiple sclerosis (MS). With new analytical platforms entering the market, standardization of serum NfL (sNfL) measurement is essential. This study compared sNfL levels across three assays – NF-light Advantage V2/Plus (Quanterix), Lumipulse G NfL blood (FujiRebio), and Elecsys NfL (Roche Diagnostics) – and derived conversion formulas for harmonization. Methods: Serum samples from three cohorts including healthy donors (n=303) and MS patients (n=181) were analyzed across three platforms. Passing-Bablok regression and correlation analyses assessed inter-platform agreement and potential systematic differences. Assays were further evaluated for their ability to detect MS disease activity. Results: All platforms showed strong correlations (Pearson>0.98; Spearman>0.90, p4 SD) on at least one platform. After excluding outliers, conversion formulas were derived to transform the values to the NF-light Advantage V2/Plus scale: NfL=6.31 × [Elecsys NfL] + 2.33 ng/L; NfL=0.94 × [Lumipulse G NfL] + 1.30 ng/L. In MS patients, all platforms detected significant differences between relapse and remission (p<0.001). Age-adjusted Z scores from converted values yielded the highest effect sizes (Cohen’s d: 0.84 for NF-light Advantage, 1.11 for Elecsys, 0.93 for Lumipulse). Conclusions: The three platforms demonstrated high correlation and comparable performance in sNfL quantification. About 3 % of samples showed strong deviations, highlighting the need for vigilance and further harmonization. Age-adjusted Z scores may enhance clinical and research utility.Keywords
This publication has 35 references indexed in Scilit:
- A French multicenter analytical evaluation of the automated Lumipulse G sNfL blood assay (Fujirebio®) and its comparison to four other immunoassays for serum neurofilament light chain assessment in clinical settingsClinica Chimica Acta, 2024
- Head-to-head comparison of four plasma neurofilament light chain (NfL) immunoassaysClinica Chimica Acta, 2024
- Biomarker Qualification for Neurofilament Light Chain in Amyotrophic Lateral Sclerosis: Theory and PracticeAnnals of Neurology, 2023
- Neurofilament Light Chain Elevation and Disability Progression in Multiple SclerosisJAMA Neurology, 2023
- Serum Glial Fibrillary Acidic Protein Compared With Neurofilament Light Chain as a Biomarker for Disease Progression in Multiple SclerosisJAMA Neurology, 2023
- Stability of the novel blood‐based biomarkers under pre‐analytical sample handling conditions: Results of the SABB‐GBSC working groupAlzheimer's & Dementia, 2021
- Absolute serum neurofilament light chain levels and its early kinetics predict brain injury after out-of-hospital cardiac arrestJournal of Neurology, 2021
- Temporal association of sNfL and gad‐enhancing lesions in multiple sclerosisAnnals of Clinical and Translational Neurology, 2020
- Association Between Serum Neurofilament Light Chain Levels and Long-term Disease Course Among Patients With Multiple Sclerosis Followed up for 12 YearsJAMA Neurology, 2019
- Approved recommendation (1987) on the theory of reference values. Part 5. Statistical treatment of collected reference values. Determination of reference limitsClinica Chimica Acta, 1987