Fluorescence-Guided Surgical Techniques in Adult Diffuse Low-Grade Gliomas: State-of-the-Art and Emerging Techniques: A Systematic Review
Open Access
Abstract
Diffuse low-grade gliomas are infiltrative tumors whose margins are not distinguishable from the adjacent healthy brain parenchyma. The aim was to precisely examine the results provided by the intraoperative use of macroscopic fluorescence in diffuse low-grade gliomas and to describe the new fluorescence-based techniques capable of guiding the resection of low-grade gliomas. Only about 20% and 50% of low-grade gliomas are macroscopically fluorescent after 5-amino-levulinic acid (5-ALA) or fluorescein sodium intake, respectively. However, 5-ALA is helpful for detecting anaplastic foci, and thus choosing the best biopsy targets in diffuse gliomas. Spectroscopic detection of 5-ALA-induced fluorescence can detect very low and non-macroscopically visible concentrations of protoporphyrin IX, a 5-ALA metabolite, and, consequently, has excellent performances for the detection of low-grade gliomas. Moreover, these tumors have a specific spectroscopic signature with two fluorescence emission peaks, which is useful for distinguishing them not only from healthy brain but also from high-grade gliomas. Confocal laser endomicroscopy can generate intraoperative optic biopsies, but its sensitivity remains limited. In the future, the coupled measurement of autofluorescence and induced fluorescence, and the introduction of fluorescence detection technologies providing a wider field of view could result in the development of operator-friendly tools implementable in the operative routine.Keywords
Funding Information
- Agence Nationale de la Recherche (EUR MANUTECH SLEIGHT-ANR-17-EURE-0026, ANR-11-LABX-0063, ANR11-IDEX-0007, ANR-11-INBS-0006, 101071040)
- Université de Lyon (EUR MANUTECH SLEIGHT-ANR-17-EURE-0026, ANR-11-LABX-0063, ANR11-IDEX-0007, ANR-11-INBS-0006, 101071040)
- Agence Nationale de la Recherche (EUR MANUTECH SLEIGHT-ANR-17-EURE-0026, ANR-11-LABX-0063, ANR11-IDEX-0007, ANR-11-INBS-0006, 101071040)
- HORIZON EUROPE Framework Programme (EUR MANUTECH SLEIGHT-ANR-17-EURE-0026, ANR-11-LABX-0063, ANR11-IDEX-0007, ANR-11-INBS-0006, 101071040)
This publication has 174 references indexed in Scilit:
- Fluorescence‐guided surgery for high‐grade gliomasJournal of Surgical Oncology, 2018
- 5-Aminolevulinic Acid–Protoporphyrin IX Fluorescence-Guided Surgery of High-Grade Gliomas: A Systematic Review2016
- 405 nm versus 633 nm for protoporphyrin IX excitation in fluorescence‐guided stereotactic biopsy of brain tumorsJournal of Biophotonics, 2015
- Use of intraoperative fluorescein sodium fluorescence to improve the accuracy of tissue diagnosis during stereotactic needle biopsy of high-grade gliomasActa Neurochirurgica, 2014
- Sodium fluorescein–guided resection under the YELLOW 560 nm surgical microscope filter in malignant brain tumor surgery—a feasibility studyActa Neurochirurgica, 2013
- 5-Aminolevulinic acid-induced protoporphyrin IX fluorescence as immediate intraoperative indicator to improve the safety of malignant or high-grade brain tumor diagnosis in frameless stereotactic biopsiesActa Neurochirurgica, 2012
- 11C‐methionine uptake and intraoperative 5‐aminolevulinic acid‐induced fluorescence as separate index markers of cell density in gliomaCancer, 2011
- Comparison of 18F-FET PET and 5-ALA fluorescence in cerebral gliomasEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Application of Intraoperative Indocyanine Green Angiography for CNS Tumors: Results on the First 100 Cases2010
- 5‐Aminolevulinic acid is a promising marker for detection of anaplastic foci in diffusely infiltrating gliomas with nonsignificant contrast enhancementCancer, 2010