Bianalyte mass detection with a single resonant microcantilever
Authors:
- 5 January 2009
- journal article
- conference paper
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (1) , 011901
Abstract
Mass-loading detection of multiple kinds of analyte with a single resonant microcantilever is proposed and experimentally validated. By exciting the cantilever in different resonance modes and adsorbing the different analytes at different locations of the cantilever, the specific mass of either kind of analyte can be independently detected. The proposed micromechanical resonant cantilever sensor is designed and fabricated using silicon micromachining techniques. Used as simulant adsorbates, Au and Cr thin films are selectively implemented on the cantilever to verify the bianalyte detecting function. The testing results are consistent with the theoretical analysis, with the detection error being an order of magnitude lower than the analyzed mass.Keywords
This publication has 12 references indexed in Scilit:
- A Latin-cross-shaped integrated resonant cantilever with second torsion-mode resonance for ultra-resoluble bio-mass sensingJournal of Micromechanics and Microengineering, 2008
- Temperature and pressure dependence of resonance in multi-layer microcantileversJournal of Micromechanics and Microengineering, 2005
- Cantilever transducers as a platform for chemical and biological sensorsReview of Scientific Instruments, 2004
- Adsorption–desorption characteristics of explosive vapors investigated with microcantileversUltramicroscopy, 2003
- Microfabrication techniques for chemical/biosensorsProceedings of the IEEE, 2003
- Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever arrayProceedings of the National Academy of Sciences of the United States of America, 2002
- Environmental sensors based on micromachined cantilevers with integrated read-outUltramicroscopy, 2000
- Equivalent circuit representation of electromechanical transducers: II. Distributed-parameter systemsJournal of Micromechanics and Microengineering, 1997
- Adsorption-induced surface stress and its effects on resonance frequency of microcantileversJournal of Applied Physics, 1995
- Resonant silicon sensorsJournal of Micromechanics and Microengineering, 1991